EPICS Release 3.13.5
Sept 2001
Changes since 3.13.4
convertRelease and checkRelease
New applications created with makeBaseApp.pl now have the functionality of
the makeConfigAppInclude.pl and makeIocCdCommands.pl scripts combined into
a single convertRelease.pl script.
The new script also provides consistency checking of the entries in the
config/RELEASE file, so that gnumake will stop with an error report if a
definition in any other <supporttop>/config/RELEASE file is different to
the same definition in this application. This checking can be disabled by
editing config/Makefile.Host.
Applications created using earlier versions of EPICS will continue to work
as before and will not benefit from the consistency check functionality.
devAiSoftRaw and devAoSoftRaw
ai and ao records using DTYP="Raw Soft Channel" can have their EOFF
and ESLO fields set manually at design or run-time, and these values will
be used when LINR=LINEAR. The same applies to any device support that
doesn't provide a special_linconv() routine; if special_linconv() is
provided however, the original behaviour occurs (EOFF is set to EGUL and
ESLO is calculated by that routine). The ESLO and EOFF fields now have CA
monitors posted if their value is changed by the special_linconv()
routine.
cac_recv_task
Increased stack size from 4096 to 819l.
drvTS
Now uses osiSock for to handle implementation diffences
Constant Links
Hex and octal constants are now accepted for constant links.
recGblInitConstantLink uses %i instead of %u for unsigned types.
This is so that hex constants are accepted. %u does not accept hex.
dbPutString makes a link constant if either strtod or strtol eats entire string.
Previously only strtod was used.
Breakpoint tables
A bug that caused an invalid conversion when the raw value is greater than the maximum table value is fixed.
If the raw value is outside the table, the aiRecord and aoRecord now specify a severity of MAJOR_ALARM instead of INVALID_ALARM.
VAL field a promptgroup
The VAL field of the following recordtypes can now be given values by database
configuration tools: aiRecord, aoRecord, biRecord, boRecord, calcoutRecord, longinRecord, longoutRecord, mbbiDirectRecord, mbbiRecord, mbboDirectRecord, mbboRecord.
Several of the changes have been made to help prevent exceptions on powerPcs
when conversions are made from float to double.
CA Server Bug
Symptoms:
Clients disconnect unexpectedly when canceling event (monitor)
subscriptions using ca_clear_event(), but this may not be noticed because the
problem is probably rare under low or moderate load, and because CA clients
automatically reconnect. The problem was only reproducible here under heavy
load presented when the R3.14 client side regression tests were run on a fast
Linux workstation. For example, when the tests were run on a 500 MHz NT host
I was unable to reproduce the bug. On vxWorks you may see threads with the
name "CA client" and also "CA event" even if there are no clients connected
(the casr diagnostic will also incorrectly report that clients are
connected). As the IOC stays in long term operation without a reboot, and
depending on the frequency of occurrence at your site (if any), you may also
notice that memory and file descriptors have been lost.
Background:
The problem was discovered when regression testing EPICS R3.14. The cause
was a deadlock occurring when a CA event (monitor) subscription was canceled
when the CA circuit was simultaneously in event (monitor) flow control mode
and the event (monitor) subscription also had a corresponding update in the
queue.
PPC float to double exceptions
Several of the changes have been made to help prevent exceptions on
powerPcs when conversions are made from float to double.
aaiRecord aaoRecord aiRecord aoRecord boRecord calcRecord calcoutRecord
compressRecord dfanoutRecord egeventRecord selRecord subArrayRecord
subRecordwaveformRecord
All DBF_FLOAT fields have been replaced by DBF_DOUBLE
dbConvert dbFastLinkConv db_access
Conversion from double to float checks for exponent too large.
dfanoutRecord.c longoutRecord.c stringoutRecord.c
OMSL did not work correctly for constant links.
compressRecord
READ_ALARM changed to LINK_ALARM
Database Channel Access Links
A message was sent to errlog whenever the connection to the server was
lost. This message is no longer generated.
drvEpvxi
National Instruments MXI-2 devices are now fully supported on both 68K and
PowerPC (the PowerPC BSP must provide code for the vxWorks intVecGet() routine
though). PowerPC CPUs that have a Universe VME interface chip will have
problems driving MXI-1 boards, although they can be made to do so by setting
the variable 'vxi_use_failed_mxi' to a non-zero value in the st.cmd file
before iocInit() and ignoring any warnings about the MXI-1 board having failed
its self-test.
If a VME-MXI-2 board will not be installed as the VME system controller
read the NOTES: towards the top of the driver source for an essential
warning.
There is special code for the National Instruments CPU030 board in this
file, which is now only included when compiling for that particular CPU board
(an entry in config/CONFIG.Vx.niCpu030 enables this).
Put Notify
A bug in dbNotifyCancel could cause a problem if a channel access client
disconnects while put notifys are outstanding.
dbAccess
A bug was fixed that was related to dynamically changing lock sets.
The record support put_array_info is called after the a put only if the put
is successful. Previosuly it was always called.
breakpoint tables
Breakpoint values are doubles rather than floats.
devVXStats
Improved algorithm for cpuUsage.
Changes since 3.13.3
Channel Access
Symptom: CA clients on all versions of EPICS with unresolved channels
broadcast search messages too frequently if an EPICS R3.13.3 server is
present. This bug does not occur if an R3.13.3 server is not present.
Changed: CA server now sends beacon messages which uniquely identify the
server address. The CA repeater was also upgraded to detect, and fix, any
problems of this nature.
Symptom: Undefined symbols show up when EPICS R3.13.3 was loaded into a PC
IOC running Tornado II.
Changed: Conditionally compiled out references to architecture
inappropriate system calls.
dfanoutRecord
- VAL and all related fields are now DBF_DOUBLE instead of DBF_LONG
- SELM, SELN, and SELL are now available. They have same semantics as for
fanout record
- PREC is now supported.
- IVOA and IVOV are no longer present. The record support never used
them.
longinRecord and longoutRecord
These did not properly set monitors when delta=0x80000000. This happened
when the record was attached to a 32 bit digital device .
Access Security TrapWrite feature
Access security now provides the ability to trap write requests coming from
a client. RULEs in the access configuration files accept an option argument
NOTRAPWRITE or TRAPWRITE. For example:
RULE(1,WRITE,TRAPWRITE)
If the additional argument is not specified the default is NOTRAPWRITE.
The purpose of this new facility is to allow things like logging Channel
Access writes. Epics base itself does not provide this ability but only the
hook needed by such a facility. DESY has developed a facility that logs CA
puts. The trap writes feacure allows the DESY facility to be implemented
without any changes to epics base. In addition it allows the user to decide
what should be logged.
This new facility will be described in more detail in the 3.14 version of
the Application Developer's Guide.
dbAccess
When obtaining graphic, control, and alarm limits, the destination values
were not initialized. If record support did not set values then the
unitialized values were returned. This caused exceptions to occut on powerPCs.
The values are now initialized to 0.
drvTS.c
- Fixed TSgetMasterTime() bug - round-trip adjustment was garbage
- Replaced TSprintf() with printf() where logging inappropriate
Changes since 3.13.2
Build Changes
- Base no longer requires the INC step. Formerly this was the first step
of build. It installed header files. By default this step is no longer
executed. If your applications need this step then in
base/config/CONFIG_SITE (for all applications) or
<apptop>/config/CONFIG (for individual applications)/CONFIG_SITE
provide the following definition
MAKE_INC_TARGET_FIRST=YES
NOTE: If your applications relies on header files being installed as
the first step of building, you should reorganize the order of building.
The 3.14 releases of base will no longer support the INC step.
- Support has been added for the Borland C++ compiler on windows installed
header files
Channel Access Changes
Fixed the RISC architecture specific problem in iocCore which results in an
intermittent and infrequent assert failure with this message: "assert
(ev_que->evUser->nDuplicates>=1u)". This was actually fixed in
release 3.13.2.
All structure members with names "m_type" were changed to "m_dataType" to
avoid a macro name compile time conflict present in the SENS IP kernel
supplied with Tornado II and optionally in Tornado I.
The network interface query code used by Channel Access to auto-configure
its address list was modified to be compatible with changed API's present in
the SENS IP kernel supplied with Tornado II and optionally inTornado I.
DBR_PUT_ACKT and DBR_PUT_ACKS
This now works for ca_put_callback as well as ca_put.
Spaces in task names
Task names no longer have any blanks
tsLib.h
Made tsStampFromLocal and tsStampToLocal public rather than private.
dbAccess
The following new routines have been added.
dbGetControlLimits
dbGetGraphicLimits
dbGetAlarmLimits
dbGetPrecision
dbGetUnits
dbGetNelements
dbGetSevr
dbGetTimeStamp
menuAlarmStat.dbd
choice(menuAlarmStat,"NO_ALARM")
is changed to
choice(menuAlarmStatNO_ALARM,"NO_ALARM")
recGblResetAlarms
a monitor for the STAT field is fired if either the STAT or SEVR changes.
Previously a monotor was fired only if the STAT changes.
dbAccess.c
In dbPutLinkValue, if the (out)link has MS property, the old severity was
propagated instead of the actual one. This is fixed by calling recGblSetSevr
with NSEV instead of SEVR of the source record.
mbboDirectRecord
- IVOV and IVOA are now fully supported. Behaviour is similar to other
output record types.
- UDF behaviour is fixed: UDF is now reset after warm reboot, after
setting any of the BX fields in supervisory mode and after (successful)
reading from DOL in closed_loop mode. Also, UDF_ALARM is raised if UDF has
not yet been reset, as with other record types
- LINK / INVALID alarm is raised if reading from DOL fails. This, also, is
similar to other output records.
devVXStats.c
The stack size for cpuUsageTask was increased. The precious stack size was
too small for mv172s, which do not have a separate interrupt stack like the
mv167. The same problem may exist on other processors such as the
powerPC.
dbel.c
It was incorrectly reporting VALUE, ALARM and LOG for all events.
longoutRecord
Added fields drvl and drvh
aiRecord, calcRecord, calcoutRecord, selRecord, and subRecord
In alarm the definitions of hihi, high, low, lolo; are changed from float
to double.
aoRecord.c
- The convert routine no longer sets udf false. Fetch_value does set udf
false when it successfully fetched a value. Thus udf is now only set false
when a new value is obtained.
- RVAL/ROFF conversion: possible range overflow is fixed. convert( ) uses
double arithmetics until the final assignment to RVAL.
dfanoutRecord.c
A dbPutLink is attempted for all links even if a put for a previous link
fails. If a dbPutLink fails recGblSetSevr(pdfanout,LINK_ALARM,MAJOR_ALARM) is
called.
dbStaticLib
When dbPutString writes to the VAL field then udf is set false.
cvtFast
cvtLongToHexString now puts 0x in frount of the number and
cvtLongToOctalString writes a leading 0.
Changes since 3.13.1
tsSubr
There was a bug when converting ascii string format to time stamp. The bug
involved the year 00 appeared in the ascii string
Channel Access
1) A severe problem where the CA client did not exit a loop sending UDP to a list of addresses
if an error condition was returned from the system call which sends a UDP frame was fixed.
This problem was discovered during load testing, and will be more likely to occur under heavy
network loading conditions.
2) A problem where the client library could fail and use a deallocated data structure if a
connection dropped while it was waiting to send a message to a client was fixed.
3) The CA client now maintains a congestion avoidance threshold on UDP search
transmissions similar to the congestion avoidance algorithm employed by modern version of
TCP. There are also some small changes related to how the search counters are maintained
without allowing them to overflow. This patch was made in R3.13.1 because I originally
identified it as the fix for (1) above, but it turned out to not be the root cause.
4) A bug fix was made for a problem where the CA repeater was inheriting on HP-UX, and
possibly other UNIX systems that are not Solaris, certain open file descriptors when
fork()/exec() are used to start the CA repeater.
5) Changes that allow CA to work on Microsoft Visual C++ 6.0 (which includes a new win
sock DLL and some changes in esoteric parts of the socket API).
6) always inform client of "no write access" for a SPC_NOMOD fields.
7) calls to ca_printf removed from rsrv.
8) prevent UDP daemon from running damaged messages with TCP protocol and
visa-versa
9) use ipAddrToA() so that address print out does not come out byte swapped on the PC
10) improved debug messages and added diagnostics
11) don't send an exception to client when bad request received over UDP.
config
- Many changes.
- Currently gdd and cas are not built.
access security
A ca exception handler was added. Thus exceptions will no longer cause the
asCa task to suspend.
dbCa
A ca exception handler. Thus exceptions no longer cause dbCa task to
suspend.
dbScan.c
pevent_scan_list->scan_list.lock was not initialized. Amazingly it did
not cause a crash. Note that the lock is only used when the scan mechanism of
records are dynamically changed.
dbCommon.dbd
- several extra definitions were changed from void * to correct struct
types.
- ACKT was changed so it can be set by database configuration tools.
dbStaticLib
- The DTYP field is always written.
- The NoRun version now keeps record instances keeps all records of each
type in alphabetical order.
- CALC fields are OK if either postfix or sCalcPostfix returns
success.
breakpoint tables
Tables names were previously forced to be alphanumeric. This restriction is
removed.
drvTS.c
- Removed potential infinite recursion from tsForceSoftSync().
- Fixed bug where time sync UDP client was getting in a state where it was
using the response from the previous request, and ending up setting the
time 10 seconds back.
drvSup.h
removed definition for reboot.
dbNotify
If dbPutNotify called dbProcess and dbProcess returned an error the notify
completion callback was called twice. This bug is fixed.
drvBB232
This support was defining storage twice. A bug in the current gcc compiler
supplied with tornado does not properl;y compile such code. The extra
definitions are removed.
aiRecord
- eoff was not being reinitialized when conversion related fields were
dynamically modified.
- hyst and lalm are changed from float to double
aoRecord
- eoff was not being reinitialized when conversion related fields were
dynamically modified.
- hyst, lalm, hihi, high, low, lolo all changed from float to double
calcRecord calcoutRecord selRecord subRecord
hyst and lalm changed from float to double
dfanoutRecord
hyst, lalm, hihi, high, low, lolo all changed from float to double
compressRecord
compressALG_N_to_1_Median (compress keeping median value) added.
mbbiDirectRecord
When just the record's severity changed, only monitors on the VAL fields
were posted, no monitors on the single bit fields.
devApsEr.c
ErGetTicks now locks while updating ticks
devCommonGpib
- sscanf response now checked to be equal to 1 rather than just not
zero.
- all mallocs changed to callocs. This is needed for the new unbundled
bitbus support.
drvGpib.c
all mallocs changed to callocs. This is needed for the new unbundled bitbus
support.
bitbus support
This support is now unbundled. DO NOT use the version in base. This
includes the following
- devBBInteract.c
- devBUG.dbd
- devBitbusStats.dbd
- devIObug.c
- drvBB232.c
- drvBB232.h
- drvBitBus.c
- drvBitBus.h
- drvBitBusErr.h
- drvBitBusInterface.h
- drvMsg.c
- drvMsg.h
- drvRs232.h
NOTE: drvBitBus.h, drvBitBus.c, drvBitBusInterface.h, and drvBitBusErr.h
appear in both base and unbundled because drvGib uses it. Must be
fixed when gpib is unbundled.
drvBBMsg.c drvBBMsg.c drvRs232.c drvTy232.h
Removedfrom base. Seemed to be old duplicate version of drvBB232.c or
not used at all.
devXxDig500Msg232.c
removed, was replaced by the digitel record type & device support
CAN and IPAC
This support has been available for some time as an unbundled product.
It is not longer included with base.
Allen Bradley
The allen bradley support has been available for some time as an unbundled
product. It is not longer included with base.
devOpt support
The following gpib support modules have been changed to fix compiler bug
for vxWorks 5.3:
- devAnalytekGpib.c
- devK486Gpib.c
- devXxDc5009Gpib.c
- devXxDg535Gpib.c
- devXxK196Gpib.c
- devXxK263Gpib.c
- devXxSkeletonGpib.c
- devXxSr620Gpib.c
mkdir.pl and rm.pl
getopt() changed to getopt "";
rc2.logServer
Moved export statements to the right place.
access security
Issue better error message if access security initialization fails.
makeBaseApp
- makeBaseApp.pl
copy any non-Apps under $top; allow links for apptype directories
fixed mistake
This now looks for all external products in config/RELEASE and generates
command to cd to product top and product bin.
calcoutRecord
Under certain conditions (an input link referencing a PV on another ioc and
an unusually long ioc initialization), the calcout record would cause an
error during iocInit by attempting to dbScanLock a record prematurely. This
anomaly has been resolved with this version. No changes to the functionality
of the calcout record were made.
dbLoadTemplate
Allow pattern with no substitutions.
devAaoCamac.c
This had an error that prevented it from compiling.
Changes between beta12 and 3.13.1
iocLogClient
If either of the environment variables EPICS_IOC_LOG_PORT or
EPICS_IOC_LOG_INET are not defined then iocLogDisable is set true, i.e.
logging is disabled. Also in the epics base distribution
EPICS_IOC_LOG_FILE_NAME and EPICS_IOC_LOG_INET are set to null.
dbCaGetTimeStamp
This is a new routine for database channel access links.
drvTS
The routine TSsetClockFromUnix was made global. Calling it forces a
resynchronization with a host time server. This is useful to
force a master timing ioc to resynchronize.
Several bugs were fixed. Previously async clients did not sync properly
with a master timing ioc. Also if an async client syncing with a unix/ntp
server got out of sync by > 1 sec then it could get out of sync by 1 to 20
seconds for an indeterminate period of time.
task_params.h
Task priorities were changed so that no epics task has higher priority
than netTask. Definitions for IOEVENTSCAN and TIMESTAMP were removed.
histogram record
Added new field PREC for display of double and float fields ULIM, LLIM,
SDEL, SVAL, SGNL, and WDTH. Added unsigned long fields HOPR and LOPR for
display of VAL array counts. Changed SDEL field from SPC_NOMOD to SPC_RESET
to allow start and stop of the watch dog timer.
Sequencer
The lex definitions have been changed so that definitions like
#define ERRVALUE 9.90E+09
are accepted.
Initial values for static variables are now honored. Previously the syntax
was permitted but the initial value was ignored. Note that initial
values will give a compilation error if the "recursive" option is used because
the assignments are within the body of a struct {} definition; it seemed
worthwhile supporting the syntax for the non-recursive case.
devMbbiDirectSoftRaw, devMbbiSoftRaw, devMbboDirectSoftRaw,
devMbboSoftRaw
SHFT was made a prompt field and also modifiable. The VAL field
of mbboDirectRecord is now modifiable.
If the fields NOBT and SHFT are given values then this device support will
honor the MASK and SHFT fields just like hardware device support. To keep
compatibilty with old databases, if NOBT is 0 during init_record, mask is set
to the value 0xffffffff. Thus old databases will act like previously
unless the nobt field was set to a non-zero value.
calcoutRecord
No longer calls dbScanLock until interruptAccept is true.
breakpoint tables
Entering negative values failed. This bug is fixed.
dbl("<record type>","<output file>","<field
list>")
The vxWorks console command dbl now allows an additional argument, which is
a list of field names.
For example
iocexample> dbl "ai",0,"DESC SCAN"
mrk:aiExample,"Analog input","Passive"
mrk:aiExample1,"Analog input No. 1","Passive"
mrk:aiExample2,"Analog input No. 2","Passive"
mrk:aiExample3,"Analog input No. 3","Passive"
June 15, 1998
All major functionality that will be in R3.13 is now in place. It has been
build on solaris, sunos, HPUX, alpha, SG, and winXX. This release is still
called a beta release but will become 3.13.1 as soon as it has been used on a
few production systems (bug fixes will be made if necessary)
The Application Developer's Guide is a major revision of the 3.12 edition.
The latest version is for beta12 base release. It is available in pdf (adobe
acrobat reader) and in postscript. The pdf format is nice for online viewing
and postscript for generating a hard copy.
LANL has a revision of the Record Reference Manual available. See the LANL
EPICS documentation.
The document "EPICS
IOC Applications: Building and Source/Release Control" provides guidlines
for developing applications with 3.13.
Changes between beta11 and beta12
IOC Applications: Building
The following explains changes that need to be made to existing applications
that followed the EPICS
IOC Applications: Building and Source/Release Control. guidelines. See the
new version of this manual for details.
Before switching applications to beta12 it is STRONGLY recommended
that you execute:
cd <top>
gnumake clean uninstall
Changes to <top>/config:
CONFIG_APP
Remove the following lines:
ifndef T_A
T_A = $(HOST_ARCH)
endif #ifndef T_A
RELEASE
If desired add a definition for TEMPLATE_TOP
RULES_TOP RULES.Db RULES.ioc RULES.iocBoot
These no longer exists in base. Replace your version with the version
from:
<base>/templates/makeBaseApp/top/config
RULES_TOP
Remove the rules for creating soft links.
makeDbDepends.pl, makeIocCdCommands.pl, replaceVAR.pl
Copy the versions from <base>/templates/makeBaseApp/top/config
makeSoftLinks
Remove this file
Changes to xxxApp/src
Move the following definitions from Makefile.Vx to Makefile.Host:
USER_DBDFLAGS
RECTYPES
DBDEXPAND
DBDNAME
MENUS
Changes to xxxApp/Db
Rules for DBFROMTEMPLATE and INDDBFROMTEMPLATE no longer exist. See the new
documentation of makeBaseApp for details of what the make rules are for
databases.
Changes to iocBoot and iocBoot/iocxxx
iocBoot no longer needs a generated nfs.cmd file
iocBoot/iocxxx no longer contains soft links. Instead the following is
done:
- A file cdCommands is generated which provides full path names for
vxWorks cd commands
- The ld commands just give a file name with no path
- The dbLoadxxx commands must specify "../../xxxApp"
aoRecord
This did not work properly if DOL is a channel access link that fails.
Semaphores
Most locking semaphores have been changed from semBCreate to semMCreate with
the options :
SEM_DELETE_SAFE|SEM_INVERSION_SAFE|SEM_Q_PRIORITY
A performance test showed that executing
semTake(sem,WAIT_FOREVER);
semGive(bsem);
in a 25MHZ mv167 took (4.4 ,7.8) microseonds when (semBCreate,semMCreate) was
used. The extra options as well as allowing a task to lock recursively are
worth the difference in performance.
Task Priorities
The priority of the channel access client for database links was changed from
100 to 68, which makes it lower than all scan tasks but higher than the
sequencer or any channel access tasks.
cvtDoubleToString
This was changed to print numbers with precision<=8 and magnitude <1e16
in fixed format with up to 3 digits after the decimal point. As an example if
PREC=1 and a number is 363000000.1 previously it was convetred to
363000000
Now it is converted to
363000000.1
All you RF folks can cheer.
Access Security
Previously it was possible to crash an IOC if access security was restarted
after iocInit. This is now fixed. Two major changes were made.
- asCaTask is no longer deleted and restarted. Instead it just clears all
channels and than adds the new channels
- The locking mechanism was changed and made more roibust and easier to
understand.
- Fixed bug that caused asRegisterClientCallback to fail on UNIX.
- asLib_lex.l changed to allow more characters(like dbLoadxxx)
- Fixed bug that could cause deadlock when an ASG field is changed at run
time.
Access Security now supports macro substitutions. A new vxWorks shell command
is:
asSetSubstitutions("var1=sub1,var2=sub2,...")
See the Application developer's Guide for details about access security.
tsdefs.h and tsSubr.c
tsTextToStamp and tsTimeTextToStamp no longer modify the pointer or the string
referenced by pText.
The nextField routines used by tsSubr were moved inside tsSubr.c and made
static routines.
drvTS
Checked for Y2K complience. It turns out it was even ok when NTP time
overflows in 2036. However it was modified so that no overflows should occur
while converting between NTP, UNIX, and EPICS epochs. In addition the
conversion of fractions of a second to nanaoseconds was changed and formatting
was changed so that interesting code does not run off right side of page.
Hopefully EPICS base is now fine for Y2K. In fact it should be fine (as far as
time is converned) until the Unix epoch overflows a 32 unsigned integer in the
year 2106.
nextFieldSubr.c
Removed from base.
vxWorks
Base now builds with either vxWorks 5.2 or vxWorks 5.3. The default is to
build vxWorks 5.3. In CONFIG_COMMON a new definition "VX_IS_TORNADO = 1" is
present. If this statemant is commented out then vxWorks 5.2 is assumed.
makeBaseApp
Only the perl version is now supported. Due to encouragement from Rozelle
Wright (LANL) and the developers at BESSY, makeBaseApp now uses template files
instead of being one huge ugly perl script. Ralph Lange (BESSY) made major
changes to makeBaseApp. It supports two sets of templates provided with base
(simple and example) as well as templates stored elsewhere. Thus each site can
add new sets of template files.
See the new WWW documentation on Application Source Release for details
dbStaticLib
The include path now supports the unix convention that an empty directory name
means the current directory. Thus the following are OK
-I nnn::mmm # Current directory is between nnn and mmm
-I :nnn # Current directory is first
-I nnn: # Current directory is last
The lex grammer was changed so that quoted strings can contain any ascii
character except a quote. A quote itself can be given as the escape sequence
\". This same change was made to dbLoadRecords and dbLoadTemplates.
For all fields in a .db file, a non null string is considered as not the
default.
For winNT the path seperator is a ;
Field attributes (psuedo fields) are now supported. In particular RTYP
(record type) and VERS (version) are now supported. In addition a new request
type DBR_CLASS is supported. See Application Developer's guide for
details.
Runtime database access
- A new routine dbGetLinkDBFtype is now available. It returns the field
type of a database link.
- dbNotify was fixed to work correctly for putNotify as well as put.
- scanppl now accepts an argument rate. scanpel accepts an
argument event_number.
base.dbd
- Soft raw device support is uncommented.
- Device support for the Allen Bradley SLC is changed.It is now:
#device(ai,AB_IO,devAiAbSlcDcm,"AB-SLC500DCM")
#device(ai,AB_IO,devAiAbSlcDcmSigned,"AB-SLC500DCM-Signed")
#device(ao,AB_IO,devAoAbSlcDcm,"AB-SLC500DCM")
#device(longin,AB_IO,devLiAbSlcDcm,"AB-SLC500DCM")
#device(longout,AB_IO,devLoAbSlcDcm,"AB-SLC500DCM")
initHooks
Changed to support initHookRegister. See Application Developer's Guide for
details. The 3.13.0beta11 version explains the new method. Note that to use
the new the startup file must contain the statement:
ld < bin/initHooks.o
If you have your own version of initHooks.c it should be changed to support
the new features. At a minumum the statement
void initHooks( int state)
must be changed to
void initHooks( initHookState state)
menuAlarmStat.dbd
The no alarm string changed from "" to "NO_ALARM"
Linear Conversion for ai and ao records:
Before beginning it should be stated that the previous linear conversion
method is still valid.
The following, which is designed by Benjamin Franksen at BESSY, is now the
recommended method:
A new field EOFF exists. The new linear conversion algorithm is now
VAL = AVAL * ESLO + EOFF
AVAL is the raw value adjusted by ASLO and AOFF.
Thus device support should now compute ESLO and EOFF instead of ESLO and
ROFF.
For example let an ADC be a 16 bits adc with raw values between -32767 and
32767.
ESLO = (EGUH - EGUL)/65535.0;
EOFF = 0.0;
NOTES:
- Device support may compute either ROFF or EOFF but not both.
- Record support sets EOFF = EGUL before calling the device init_record.
This is done so that for old device supports (those that do not set the
EOFF field) the above formula becomes:
VAL = AVAL * ESLO + EGUL
The original bi-polar adc device support modules added a "bias" to the raw
value so that the raw value is >= 0. When they were written neither RVAL or
EOFF existed.
RISC architectures
Some changes were made to build on RISC architectures. A new include and
source file (adjustment.h and adjustment.c) were created to aid this support.
We can thank Peregrine McGehee for this new support.
errlog
This is a replacement for the old code that implemented errMessage, errPrintf,
and epicsPrintf. It provides for multiple system wide error loggers. The
existing iocLog has been modified to use the new code. The new code supports
the old calls and adds some new calls. See Application Developer's guide for
details.
devABSLCDCM
Changed Scl to Slc wherever this occured. Added support for signed 16 bit
analog values. Stephanie Allison (SLAC) made these changes.
devMpc
Removed from base.
devVXStats
Major rewrite of this routine. It computes the cpu usage via a low priority
taks rather than using spy. It reports file descriptor usage rather than tcp
connections (this is what is actually measures). The format of the INP ,and
OUT fields has changed since the previous version. The new device definitions
are:
device(ai,INST_IO,devAiVXStats,"VX stats")
device(ao,INST_IO,devAoVXStats,"VX stats")
The INP fields now have the form
field(INP,"@memory")
field(INP,"@cpu")
field(INP,"@fd")
The OUT fields now have the form
field(OUT,"@memoryScanPeriod")
field(OUT,"@fdScanPeriod")
field(OUT,"@cpuScanPeriod")
The source file has comments showing a sample database.
devSymb
This has been drastically changed. Look at <base>/src/dev/symbDev/README
for details.
CA Client Library
Problems where 3.13.beta11 clients were unable to connect to 3.11 and receive
the correct native type have been fixed. The CPU is now consumed more
efficently by CA tasks waiting in select() under vxWorks. The client lib now
detects an IOC reboot when that reboot is faster that EPICS_CA_CONN_TMO. CA
now runs better on systems without local interface query capabilities
(currently only cygwin32).
C++ Channel Access Server - CAS
The constructor for class casPV no longer requires a reference to the server.
For backward compatibility a reference to the server may still be supplied,
but it will not be used. The C++ Portable Channel Access Server Library now
builds on VMS. A really bad bug was fixed in the example directory server when
clients use PV names with ".xxxx" (a field name) in them.
Global Data Descriptor Class - GDD (only used by the C++ CA server)
A bug occurring when the primitive type was changed to/from aitSting and the
constructor/destructor member functions for class aitString were not run has
been fixed. A bug occurring when class GDD changed the bounds on the
destination GDD has been fixed. A smart pointer class for GDD was added. This
class automatically maintains the GDD's reference count so that the GDD will
not be deleted until the last smart pointer class pointing to it is deleted.
Moving this responsibility to a class will greatly reduce the probability of
making a mistake in application code.
WIN32 (PC) Port of EPICS
Winsock II is now required. This allows CA to properly execute
EPICS_CA_ADDR_LIST=YES. Windows NT 4.0 comes with Winsock II. A properly
functioning Winsock II for Windows 95 can be obtained form
http://www.microsoft.com/windows95/info/ws2.htm. Beware of buggy versions of
Win95 Winsock II that are sometimes installed by 3rd party products. A static
(no EPICS DLLs) build of EPICS on WIN32 is now supported. The EPICS CA
repeater is now automatically started under WIN32 if it isnt running. At Ken
Evans' request GUI programs will this release _not_ allocate a console for
messages from EPICS libraries unless base is compiled with host optimisation
turned off (HOST_OPT=NO). If you would like to see messages from EPICS base
libraries when using an optimised build, then start GUI programs from a DOS
window.
EPICS Environment Variables that Include Host IP Addresses
It is now possible to use DNS host names in addition to dotted IP addresses in
EPICS environment variables. All operating systems that have a DNS client
implementation should allow this. Currently only vxWorks does not, and so if
you would like to use real host names instead of dotted IP addresses on
vxWorks you must use the "hostAdd()" function to add host name / IP address
pairs from your system start-up script. For Example: hostAdd
("mercury_dirigible","100.20.30.40") putenv
("EPICS_IOC_LOG_INET=mercury_dirigible")
GCC 2.8
The host portions of EPICS now build correctly with GCC 2.8
Changes between beta4 and beta11
Support for win95 and winNT
Epics base now builds on windows platforms
GDD and Portable Channel Access Server
The gdd library and the portable channel access server now build on all
platforms, except SGI and cygwin32, listed above. This also means that C++ is
supported on these platforms.
Application Developer's Guide
The chapter "Building IOC Applications" is gone. It is replaced by the
document "EPICS IOC Applications, Building and Source/Release Control". Other
changes are minor. Following is a brief list:
- Database Definition: General Rules describes escape sequences
- Record Support: All record support methods that accept DBADDDR * now use
the routine dbGetFieldIndex instead of comparing addresses. IOn addition
the get_enum_str routines now use paddr->pfield as the field address
instead of the field in the record.
- Runtime Database Access: Gives brief description of DBR_PUT_ACKT and
DBR_PUT_ACKS. Also describes new routine dbGetPdbaddrFromLink
- The chapter "IOC Initialization" describes how to configure the error
message logger.
NOTE:The initHooks described in the appDevGuide is not in beta11. In
beta11 initHooks is the same as previous releases. The new version will be in
the next release.
Compiler warning messages:
All of base except drv/old is now being built with
VX_WARN_YES = -Wall -pedantic -ansi
Most warning messages have now been eliminated. The remaining messages should
not be removed without looking hard at code.
recSubArray
get_control_double routine returned incorrect values for fields INDX and NELM.
devAiStats
This is now renamed devVXStats. The new device definitions are:
device(ai,VME_IO,devAiVXStats,"VX stats")
device(ao,VME_IO,devAoVXStats,"VX stats")
Thus if an application has an old base.dbd and baseLIBOBJS including
definitions for this device support they must be modified.
SysMon device support
This is removed from base. It is for APS designed and build VME create system
monitoring. The support code is available from APS if needed. NOTE: In some
beta releases baseLIBOBJS, had an include for devSysmon.o. Applications using
an old version of baseLIBOBJS will not build until this statement is deleted.
dbToRecordtypeH
The enums for menus had a comma after last item.
pulseTrainRecord
recGblInitConstantLink for sgl was referencing wrong field.
gphLib
This did not properly support multiple clients in multi-thread environment.
dbPvdLib
Modified to be faster.
devMz8311
Use maxCards from module_types.h instead of a #define
calcRecord
Allow CALC to be 40 characters. Increase rpbuf from 184 to 200
mbbiDirectRecord
Add call to refresh_bits.
mbbxDirectRecord
Bx becomes no prompt for mbbi and prompt for mbbo. It was the reverse before.
calcoutRecord
A new record type that replaces old wait record. It is like a calc record with
an output and a delay. It makes the wait record obsolete.
dbAccess
dbGetPdbAddrFromLink is a new routine. It returns NULL for all except LINK_DB
links, for which it returns the address of the associated DB_ADDR structure.
escape characters in database files
dbLoadDatabase, dbLoadRecords, and dbLoadTemplate all allow the standard C
escape sequences in quoted strings. For example a string can contain: "\x00
\27 \t" Thus these sequences pass though the lexical analyzer .
dbTranslateEscape
A new routine in libCom. It is used to translate escape sequences. It is
defined in file epicsString.h. It typical place to use this is on parm fields
that contain escape sequences like "\x00 \27 \t".
Slow booting
iocs with big databases were taking a long time to boot. It was discovered
that allocating and then freeing small amounts of memeory frequently resulted
in a VERY long memory free list. This is now fixed.
boRecord, mbboRecord
init_record now initialized the RVAL field.
ProcessCallback
Benjamin Franksen at BESSY reported a serious bug in the routine
ProcessCallback (not used in base). It has been fixed.
CALC fields
postfix and calcPerform (used by calcRecord) have been changed so that a 0
byte now ends the postfix expression. Also if postfix detects an illegal
expression it generates a 0 length postfix string. When calcPerform is given a
0 length string it returns a error status. Thus calcRecord no longer causes
the IOC to crash if an illegal CALC fields is loaded.
Etc.
Many other minor problems, bugs, etc. were fixed.
Notes for Release 3.13 of EPICS Base
For Release 3.13 major changes have been made to EPICS base. The IOC
Application Developer's Guide has been extensively modified and now describes
release 3.13. If you are upgrading for a 3.12.xxx or earlier release you
must obtain and read the new App Dev Guide.
In porting EPICS to multiple architectures, the previous method of using
utilities to convert the database definition files to a binary file (default.dctsdr)
caused problems. The problem is that the binary file is created on one
architecture and used on another. This has worked so far for sun4 and hp
hosts combined with motorola 68xxx processors. As support for more host
and more ioc architectures is developed problems are appearing. This paper
describes changes that solve the problems.
Because the changes result in extensive changes to database access,
other changes are also made. The file syntax is changed. The internal database
structures are simplified and also changed to make it easier to support
runtime add/delete of record types and record instances.
Goals
-
Allow database definition without an EPICS generated binary file.
-
Change internal database structures so that runtime add/delete of record
types and record instances is possible.
-
Allow each ioc to load and initialize only the record, device, and driver
support it actually uses.
Backward Compatibility
-
Minimal changes to existing record/device/driver support. A section below
describes necessary changes.
-
Provide tools to generate new database files from existing default.dctsdr
-
No or almost no incompatible changes to the dbStatic API. New capabilities
are of course allowed.
Incompatibilities
-
DCT is no longer supported. A TCL/TK replacement is now available.
-
The sdr file format (.database files) is no longer supported.
-
The old DCT short form format is no longer supported.
-
The only way to load record instance definitions into an ioc is the record
instance format, which is exactly the same as the GDCT .db format.
-
Any user written code that accesses internal database structures, i.e.
any code that uses anything described in Chapter 11 (Database Structures)
of the old Application Developers Guide will have to be changed.
Overview of new database support
EPICS defines a set of database file formats. In addition any of these
files can contain include statements. For each ioc, the application developer
will create a set of files specifying the record types, devices, and drivers
needed for that ioc. Normally a master file will be created which consists
of include statements that bring in record, device, and driver definitions.
Default configurations can be provided for new users or for particular
applications.
Database configuration and utility tools access the database via the
static database access library. This library reads the files. It provides
routines for reading the information in the database and for creating and
modifying record instances. Database definition files can be read incrementally.
Other database configuration tools (capfast, relational database systems,
object oriented databases, etc.) can also be used as long as they generate
record instances in the format described below. In this case, however,
it is still necessary to generate the other files because they are needed
by database access and for record and device support modules.
Tools are provided that generate C code from the database files. Header
files are generated for menu and record type definitions. These header
files are used by record and device support. In addition the record type
definitions contain code which computes field offsets and sizes and record
sizes. This code is compiled by the same cross compiler that is used to
compile other ioc code. Thus cross platform compatibility is achieved.
In order to initialize an ioc, all files needed by that ioc have to
be loaded. It is also necessary to load the record/device/driver support
modules.
Everything is designed so that the following are possible:
-
It is easy to tailor record/device/driver support individually for each
ioc.
-
It is possible to incrementally add definitions. For example database configuration
tools do NOT have to load all definitions at startup. New definitions can
be read at any time. The underlying structures are designed so that it
is possible to add new definitions after an ioc is initialized. Note however
that additional changes will be needed after this project is complete before
on-line add and delete are possible.
-
It is possible to completely unbundle record support, device support, and
driver support. Again work will remain before this is a reality.
An additional feature is that, for database configuration tools, record
instance numeric fields and menu fields are stored as character strings.
This solves the following problems.
-
Rounding problems caused by converting from string to float and then back
to string disappear.
-
For integer fields the user can use the standard c conventions of preceding
the value with 0x for hex or 0 for octal. Since the string itself is stored,
the value will always appear with the prefix.
-
Macro definitions are allowed.
Another feature is is that it is now possible to distinguish link constants
with a value of 0 from links that have never been given a value.
Other changes have been made while the opportunity was available.
-
The config files have been changed considerably. Base now has it's own
config directory. Extensions (not implemented) can use the config from
the version of base against which it is built as well as supply additional
config files.
-
Field names are no longer limited to four characters. It is NOT a good
idea to use this feature until it has been checked against existing channel
access clients. If fact it has not been tested at all.
-
The record support modules have been renamed from recXxx.c to xxxRecord.c.
This the name of the database file, include file, and source file are the
same. Only the extensions are different.
-
All files in base/include have been moved to an appropriate base/src directory.
These files are now installed into base/include.
Database Definition File format
Formats are defined for the following:
-
Menu choices.
-
Record type description
-
Device choice
-
Driver choice
-
Breakpoint Conversion Table
-
Record Instance.
See the Application Developer's Guide for details.
The menu choices replace the existing global, record, and conversion
choices. The global and record choices are very similar and thus are easy
to combine. The method of handling the old conversion choices is described
below. That section also describes the breakpoint tables.
The record type description format has been completely changed. It now
has a "real" syntax. It should be MUCH easier to generate new definitions.
The device choice and driver support definitions are defined so that
it is easy to provide incremental definitions.
The record instance format is an extension of the 3.12.beta13 and later
GDCT .db format.
Path and include statements are supported. This provides a powerful
tool for combining definitions from many sources. The path is a unix style
path, i.e. a colon separated list of directory names.
default.dctsdr conversion tools
NOTES
-
In the following default.dctsdr is optional. If not given the tool just
looks for the file "default.dctsdr" in the current directory.
-
All output files are placed in the directory from which the tool is executed.
The following tools are provided:
-
sdr2gblmenu [default.dctsdr]
All global menus are written as separate files.
-
sdr2recordtype record_type record_type.h [default.dctsdr]
A record type definition file is generated.
-
sdr2device [default.dctsdr]
All device definitions are placed in a file called device.dbd
-
sdr2driver [default.dctsdr]
All driver definitions are placed in a file called driver.dbd
For all utilities the required database definition files are generated
from a dctsdr file from a previous epics release. A dctsdr file can be
specified or else the utilities can be run in a directory which contains
default.dctsdr (or a soft link with that name). sdr2recordtype also requires
the header file generated by a previous epics release.
Conversions - replacement for DBF_CVTCHOICE
Let's briefly review database conversion, i.e. the LINR field for ai and
ao records.
The allowed conversions are:
-
None
-
Linear
-
Breakpoint Tables
The main complication results from the breakpoint tables. Previously EPICS
handled breakpoint tables as follows:
The user prepares files in one of two formats: The first is just a list
of "raw value, eng units value". The second format is a file with a header
line followed by a table of raw data values that represent data at equally
spaced engineering unit values. In either case the ascii data is converted
to an internal binary format containing breakpoint tables. This data is
part of default.dctsdr.
Here is how breakpoint table are now handled.
-
A new file format is defined for breakpoint tables.
-
A conversion tool, makeBpt, takes as input the second format described
above and creates the breakpoint table in the new file format.
-
Previously EPICS automatically provided breakpoint tables for TypeJdegC,
TypeJdegF, TypeKdegC, and TypeKdegF thermocouples. These breakpoint tables
are part of the new epics base. However there are only loaded into an ioc
if the user includes their definitions.
-
A regular menu definition file menuConvert contains the same definitions
as choices as that provided by the 3.12.2 version of epics. The menu includes
definitions for the epics supplied breakpoint tables.
-
The ai and ao records call a routine cvtRawToEngBpt to perform breakpoint
conversions. This routine has been rewritten to to look for breakpoint
tables obtained from the new breakpoint file format.
One other comment needs to be made about conversions. The Allen Bradley
device support for the IXE module uses the LINR field in a non standard
way. This was a mistake but compatibility must be maintained. Thus menuConvert
contains a lot of choices used only by the IXE device support.
Converting existing applications
Database Configuration Tools
DCT - Rather than making major changes to DCT, a TCL/TK replacement has
been written. The executable is named DCT313.
GDCT - A new version is provided that supports 3.13. The executable is
named GDCT313.
CAPFAST
-
The filter that converts record instance definitions must generate the
new record instance file format rather than the old short form report.
Contact Roselle Wright at LANL for details.
-
A tool should be developed that, using static database access, automatically
generates the record type description files used by capfast. My guess is
that this should be easy to do.
Application Source/Release Control
At the present time There are at least three Application Source/Release
Control Systems in active use. The old technique of having cat_ascii and
replace_ascii directories no longer work. In addition makesdr no longer
exists. The new system offers developers far more flexibility but it also
means that each Application Source/Release Control system has to be modified
to take advantage of the new capabilities. Again the changes in RULES and
makeBaseApp should make this task easier.
The document "EPICS
IOC Applications: Building and Source/Release Control" describes a
utility makeBaseApp which can be used for small applications. It also provides
guidlines that can be used for large applications.
Locally developed Record/Device support
-
The dctsdr file and any header files for locally developed record types
must be saved before performing a getrel to a new version of base.
-
Any global menus, not supplied with epics, have to be converted via the
sdr2gblmenu tool. The generated file must be edited to extract the locally
developed menus.
-
Any locally developed record type definitions have to be converted to the
new ascii file format via the sdr2recordtype tool. Note that the generated
file also contains definitions for any record specific menus.
-
New definitions for locally developed device support must be generated
via the sdr2device tool. The generated file must be edited so that only
locally developed device support remains.
-
New definitions for locally developed driver support must be generated
via the sdr2driver tool. The generated file must be edited so that only
locally developed drive support remains.
-
If breakpoint tables have been locally developed. The following should
be done.
-
The menuConvert file should be copied from epics and new entries for the
local breakpoint tables added to the end.
-
If raw breakpoint tables were previously used, convert them to the new
breakpoint format (easy to do). If equally spaced data files were used
the makeBpt tool can be used to create new breakpoint tables.
-
The following changes must be made to the record support modules:
-
The include statement for the record type h file must be surrounded by
the statements:
#define GEN_SIZE_OFFSET
#undef GEN_SIZE_OFFSET
Any statements that initialize a field from constant links must be changed.
Such statements always contain the characters "value.value". For example:
pai->simm = pai->siml.value.value;
is changed to
recGblInitConstantLink(&pai->siml,DBF_USHORT,&pai->simm);
NOTE: This change also has to be made to any device support that manipulates
constant links. Normally this is only soft device support.
Because it is now possible to distinguish between null links (links
that were never given a value) and CONSTANT links with the value 0, the
code now handles initialization of constant links in a uniform manner.
Several record types in previous versions had special code to handle the
case of the value 0 for constant links. These have been changed.
If record support uses menus it should be modified to use the enum definitions
in the generated header files.
dbStaticLib - Some routines have a new name:
OLD ROUTINE REPLACEMENT
dbFindRecdes dbFindRecordType
dbFirstRecdes dbFirstRecordType
dbNextRecdes dbNextRecordType
dbGetRecdesName dbGetRecordTypeName
dbGetNRecdes dbGetNRecordTypes
dbFirstFielddes dbFirstField
dbNextFielddes dbNextField
dbGetChoices dbGetMenuChoices
For now the old version will be supported. After one release they will
go away.
New vxWorks CONFIG rules are available to generate menu and record type
include files from ascii files. The rules are:
MENUS += menuXXX.h
RECTYPES += xxxRecord.h
Changes to recGbl and database access link routines.
-
recGblInitFastInLink
recGblInitFastOutLink
All code calling these should be removed. They are no longer needed.
-
recGblGetFastLink
recGblPutFastLink
dbFastLinkGet
dbFastLinkPut
recGblGetLinkValue
recGblPutLinkValue
These are replaced by
dbGetLink dbPutLink
long dbGetLink(struct db_link *,short dbrType,
void *pbuffer,long *options,long *nRequest);
The last two arguments can be 0. options=0 means no options. nRequest=0
means scalar, i.e. retrieve one value.
long dbPutLink(struct db_link *,short dbrType,
void *pbuffer,long nRequest);
dbCaAddInLink
dbCaAddOutlink
dbCaGetLink
dbCaPutLink
The Add routines are no longer needed. The Get/Put routines are replaced
by dbGetLink/dbPutLink.
link.h
All parm fields are now declared char * parm rather than char parm[]
In addition the defines INSTIO_FLD_SZ to VXI_PARAM_SZ no longer exist.
This is done so that unused links now use less storage.
Record Instance Definitions
Convert to proper format
All record instances must be capable of being loaded into an ioc via dbLoadDatabase,
dbLoadRecords, or dbLoadTemplate. This is the same format that dbLoadRecords
and dbLoadTemplate used in 3.12 releases. Note that if any files contain
the statements:
database(x) { nowhere() {
}
}
or
database(x) {
}
These statements must be removed. They were in pre 3.12 releases.
CONSTANT Links with value "0"
Release 3.13 is now capably of distingushing between a null link (a link
that is not given any value at all) and a constant link with the value
0. This cause problems for some old record instance files. For example
if a record instance is defined as:
record(fanout,name) {
field(SELN,"1")
field(SELL,"0")
}
Such definitions can be fixed by either completly removing the link definition
or changing the value from "0" to "".
here is a complete list of record types and fields that may have this
problem:
-
fanoutRecord
-
SELL -> SELN Note SELN is not a prompt field.
pulseCounterRecord
pulseDelayRecord
pulseTrainRecord
-
SGL -> HGV
NOTE: This is a bug. The field should be SGV. Fixed 3.13.beta5.
selRecord
-
INPA -> A NOTE A is not a prompt field
-
INPB -> B NOTE B is not a prompt field
-
... for all INP links
seqRecord
-
SELL -> SELN NOTE SELN is not a prompt field
stringinRecord
-
SIOL -> SVAL NOTE SVAL is not a prompt field
stringoutRecord
A good way to find these problems is to use grep. For example:
grep SELL */*.db
This assumes that you are in directory that contains subdirectorys containing
.db files.
IOC Startup files
The command dbLoad is no longer supported. The new method is to issue one
or more dbLoadDatabase commands and any combination of dbLoadRecords and
dbLoadTemplate commands.
Other Release Notes
IOC Test routines
Many changes have been made to the EPICS ioc test routines, i.e., routines
given to the vxWorks shell. Please read the chapter "IOC Test Facilities"
in the Application Developer's Guide for details.
Changes to Record and Device Support
-
Changes to record support modules (caused by looking for UDF problems)
-
aaiRecord, aaoRecord - The siol field, which was never used in record processing,
has been removed from aaiRecord.dbd and aaoRecord.dbd files. Old style,
pre R3.12, c code in init_record was updated.
-
compressRecord - Now allows Channel Access links for INP. It also sets
READ_ALARM if it has bad or no input.
-
dfanoutRecord, longoutRecord - In process the udf field is set to false
when dbGetLink returns success only if dol is not a constant link.
-
fanoutRecord - Now supports CA links. Same rules as FLNK.
-
biRecord, mbbiRecord - Udf now set to false in put_enum_string when val
is initialized.
-
mbbiDirectRecord - Udf now set to false in process when val is initialized.
-
mbbiDirectRecord, mbboDirectRecord, waitRecord - Old style, pre R3.12,
c code in init_record was updated.
-
pidRecord - Changes made to modify DB_LINK test on cvl field to allow type
CA_LINK.
-
pulseDelayRecord - Removed code that called recGblSetSevr is status non
zero just before return. process always returns 0.
-
pulseTrainRecord - process always returns 0.
-
seqRecord - Changes made to modify DB_LINK tests on the lnk and dol fields
to allow type CA_LINK.
-
steppermotorRecord - In process the udf field is now set to false if dol
is not a constant link and dbGetLink returns success. Changes made to modify
DB_LINK test on rdbl field to allow type CA_LINK.
-
stringoutRecord - In process the udf field is now set to false if dol is
not a constant link and dbGetLink returns success.
-
waveform record - While processing the udf field is now set to false if
simulation mode is TRUE and siol is not a constant link and dbGetLink returns
success.
-
Device Support Changes
-
devAiSoft, devBiSoft, devEventSoft, devLiSoft, devMbbiDirectSoft devMbbiSoft,devSiSoft
- In init_record the udf field is set to false only if inp is a constant
link and recGblInitConstantLink returns success. In read_xxx the udf field
is set to false only if inp is not a constant link and dbGetLink returns
success.
-
devAiSoftRaw, devBiSoftRaw, devMbbiDirectSoftRaw, devMbbiSoftRaw - In init_record
the udf field is no longer set to false if inp is a constant link and recGblInitConstantLink
returns success (rval, not val, was successfully initialized).
-
devLoSoft, devLoSymb, devMbboDirectSoft, devMbboSoft, devPtSoft, devSoSymb
- The udf field is no longer set to false in write_xxx.
-
devHistogramSoft, devHistogramTestAsyn - In init_record the udf field is
set to false only if svl is a constant link and recGblInitConstantLink
returns success.
Make rules and config files
The config environment has been extensively changed. BASE now has its own
set of config files. Extensions will be able to use the base config files
(for the version of base it is built against) and add it's own definitions.
Changes to extensions will come at a future time.
GNU C++ for base
It is now possible to compile 3.13 EPICS base with the gnu C and C++ compilers.
A C++ compiler that properly supports templates is required to build the
new ca server and the gdd library.
log server
Thanks to William Lupton at KECK the log server will now (under the latest
EPICS 3.13) obtain a new directory for the log file in response to SIGHUP.
CA repeater fix
Thanks to Kim Gillies, Bret Goodrich, and others at NOAO a problem has
been discovered and fixed in the 3.12 CA repeater under solaris.
Portable CA server
A new CA server C++ class library is available. The server library is in
libcas.a. The API is described in casdef.h. Doc is in progress. An example
server tool can be found at base/src/cas/example. The server has been tested
under sunos4 and solaris. A multi-threaded version of the new server for
vxWorks is in progress.
Macro Substitution Library
The macro substitution library discussed in tech-talk is now part of epics
base. Thus was contributed by Bill Lupton. The static database library
uses this library. dbLoadRecords and dvbLoadTemplate also use it.
VXI Resource Manager fix
Thanks to Ric Claus of SLAC a bug has been isolated in the VXI resource
manager.
Symptom: correct slot isnt located when EPICS_VXI_LA_BASE is set to
something other than zero.
Access Security
If asSetFile has been set in a startup file and access security initialization
fails, then iocInit returns -1 so that startup file does not finish.
errPrintf
On Unix this now calls fprintf(stderr instead of printf
iocLogClient.c
This now calls printf instead of epicsPrintf to prevent deadlocks.
Native type for DBF_USHORT
Formerlly old database access, which does not have unsigned short called
the native type DBR_FLOAT. It now calls it DBF_LONG
Allen Bradley Driver
Analog Output Block Transfers were being requested too frequently
If link_status command fails (3 times in succession) adapters are now
immediatly declared down.
For btRead and btWrite, The driver now enforces a timeout of 5 seconds
which is 1 second more than scanner itself enforces. This is so that if
scanner throws away a BT request it will still timeout.
For btRead and btWrite is is no longer permissible to issue a new btRead
or btWrite from tha callback routine.
The on line doc has the following two changes:
-
abConfigBaud has arguments (link,number) (Old doc was wrong)
-
Now states that new btRead/btWrite can NOT be ussued from callback.
vmic2534
Support has been added by LBL. It still needs to be ansified.
New options for links
FWDLINK
A forward link now works between IOCs but only if the field is PROC.
When recGblFwdLink is executed, a 1 is written.
OUTLINK new option CA (In addition to PP and NPP)
CA means always make it channel access link
INLINK new options CA CP CPP (In addition to PP and NPP)
-
CA means always make it a channel access link
-
CP means CA + process when monitor occurs
-
CPP means CA + process passive records when monitor occurs
dbAccess (dbGetField dbPutField) make sure that link field strings are
not longer than 39 characters. They allow M for MS and N for NMS
callback and scan task names
The task names have been changed to make them unique
dbPutString
If the strlen of the new field is >= field_size an error is returned.
event scanned records
Multiple priorities are now supported.
WARNING: Default PRIO is low thus old event scanned records may be
executed at a lower priority then previous release.
Allen Bradley Stepper Motor Support (Ric Claus SLAC)
Support for the allen bradley stepper motor is available. See the APS EPICS
Hardware Support page for details.
initHooks
INITHOOKafterCaLinkInit1 is replaced by INITHOOKafterCaLinkInit