Using SRS_PS300 instrument support in an application

This  module provides support for the Stanford Research Systems PS300 series of high-voltage power supplies, including the PS310, PS325, PS350, PS355, PS365, PS370 and PS375.

Several files need minor modifications to use SRS_PS300 instrument support in an application.

  1. Add the full path to the SRS_PS300 support directory to the application configure/RELEASE file:
    SRS_PS300=xxxx/modules/instrument/SRS_PS300/<release>
    Where <release> is the release number of of the SRS_PS300 support.
  2. Add stream and asyn support to application database definition file
    The application database definition file must include the database definition files for the stream package and for any needed ASYN drivers. There are two ways that this can be done:
  3. Add the stream and asyn support libraries to the application
    You must link the stream support library and the ASYN support library with the application. Add the following lines:
    xxx_LIBS += stream
    xxx_LIBS += asyn
    before the
    xxx_LIBS += $(EPICS_BASE_IOC_LIBS)
    in the application Makefile.
  4. Create an ASYN port in the application startup script.  For example, the commands to set up a connection to a PS300 power supply through a LAN/Serial adapter are:
    drvAsynIPPortConfigure("L0","serialps300:4003 COM",0,0,0)
    asynSetOption("L0", -1, "baud", "9600")
    asynSetOption("L0", -1, "bits", "8")
    asynSetOption("L0", -1, "parity", "none")
    asynSetOption("L0", -1, "stop", "1")
    asynSetOption("L0", -1, "crtscts", "N")

  5. Load the SRS_PS300 support database records in the application startup script:
    cd "$(SRS_PS300)"      (cd SRS_PS300 if using the vxWorks shell)
    dbLoadRecords("db/devSRS_PSxxx.db,"P=<P>,R=<R>,PORT=<PORT>,A=<A>")
    where xxx specifies the type of supply (310_pos, 310_neg, 325_pos, 325_neg, 350_pos, 350_neg, 355, 365, 370 or 375).  You'll have to provide appropriate values for the PV name prefixes (<P> and <R>), the port name (<PORT>) and the device address (<A>). The port name must match the value specified in the ASYN drvyyyyConfigure command.

Installation and Building

After obtaining a copy of the distribution, it must be installed and built for use at your site.
  1. Create an installation directory for the module. The path name of this directory should end with modules/instrument/SRS_PS300.
  2. Place the distribution file into this directory.
  3. Execute the following commands:
    cd modules/instrument/SRS_PS300
    gunzip SRS_PS300<release>.tar.gz
    tar xvf SRS_PS300<release>.tar
    cd <release>
    Where <release> is the release number of of the SRS_PS300 support.
  4. Edit the configure/RELEASE file and set the paths to your installation of EPICS base, stream and ASYN support modules.
  5. Execute make in the top level directory.