Roger~thank you and Ralph very much!
在2008-10-15,"Owens, PH (Peter)" <[email protected]> 写道:
>Not in that case.
>
>Some devices output binary numbers as strings of symbols
>eg "!!!!.!.!" for 0xF5
>that can be parsed with the %B converter.
>
>dfanout would send the same data to all the records,
>which is not what you want, but in any case
>I would recommend Ralph Langes suggestions.
>
>Pete
>
>> -----Original Message-----
>> From: [email protected]
>> [mailto:[email protected]]On Behalf Of Silver
>> Sent: 15 October 2008 15:54
>> To: tech-talk
>> Subject: Re: RE: a question about mbbiDirect and fanout
>>
>>
>> hi, Owens:
>>
>> Thank you very much~~~ your answer solved my much
>> confusion. But about "Depending on the serial protocol you
>> might be able to change the stream protocol file", can you
>> give me more explaination? I use "%1r" toe match the 8bit
>> value such as 0xfe, you means can do some calculation by some
>> string operator like C++?
>> ps, I checked the record manual, seems I can use both
>> dfanout and seq record to implement your answer 3, am I right?
>>
>> ======= At 2008-10-15, 21:48:10 you wrote: =======
>>
>> >Three possibilities:
>> >
>> >1. use a chain of FLNKs
>> >2. use two fanout records.
>> >3. use a seq record
>> >
>> >Why do you need the NOT value?
>> >You could just assign ZNAM to ON rather than OFF in your bi record.
>> >Depending on the serial protocol you might be able to change
>> the stream protocol file.
>> >In an case, I don't think a calc record has B0,B1,...
>> fields, so you would need
>> >a second mbbiDirect record.
>> >
>> >eg.:
>> >record(mbbiDirect,"$(PREFIX):DISTATE")
>> >{
>> > field(DTYP, "stream")
>> > field(INP, "@power.proto mbbiDirect_distate_raw terminal")
>> > field(SCAN, "1 second")
>> > field(PINI, "YES")
>> > field(FLNK, "$(PREFIX):DIOSTATE")
>> > field(NOBT,8)
>> >}
>> >
>> >record(bi,"$(PREFIX):DI0STATE")
>> >{
>> > field(DESC, "MAIN RELAY")
>> > field(INP, "$(PREFIX):DISTATE.B0")
>> > field(ZSV, "NO_ALARM")
>> > field(OSV, "MINOR")
>> > field(ZNAM, "On")
>> > field(ONAM, "Off")
>> > field(FLNK, "$(PREFIX):DI1STATE")
>> >}
>> >
>> >
>> >> I want to get a raw value(8 bit) from hardware, after
>> >> caculating the NOT value of it, 8 bi records will get the
>> >> each bit value. For example, if I get the raw value "0xFE",
>> >> caculate it with NOT operator to "0x01", then bi record 1th
>> >> get the B0 bit, bi record 2th get the B1 bit...etc.
>> >> If I set SCAN field to period of each bi record, maybe I
>> >> can refresh the value. While is it possible only setting SCAN
>> >> field of mbbiDirect record, then arosing all bi records being
>> >> processed?
>> >> I know if I use a fanout record(maybe dfanout record since
>> >> fanout only support 6 values), I can do this. Is there any
>> >> other possible way?
>> >> ps, is there any other way to caculate the NOT value
>> >> without using calc record?
>> >>
>> >> record(mbbiDirect,"$(PREFIX):DISTATE_RAW")
>> >> {
>> >> field(DTYP, "stream")
>> >> field(INP, "@power.proto mbbiDirect_distate_raw terminal")
>> >> field(SCAN, "Passive")
>> >> field(PINI, "YES")
>> >> field(FLNK, "$(PREFIX):DISTATE")
>> >> field(NOBT,8)
>> >> }
>> >>
>> >> record(calc,"$(PREFIX):DISTATE")
>> >> {
>> >> field(CALC, "~A")
>> >> field(INPA, "$(PREFIX):DISTATE_RAW.VAL NPP")
>> >> }
>> >>
>> >> record(bi,"$(PREFIX):DI0STATE")
>> >> {
>> >> field(DESC, "MAIN RELAY")
>> >> field(SCAN, "1 second")
>> >> field(INP, "$(PREFIX):DISTATE.B0 PP")
>> >> field(ZSV, "MINOR")
>> >> field(OSV, "NO_ALARM")
>> >> field(ZNAM, "OFF")
>> >> field(ONAM, "ON")
>> >> }
>> >>
>> >> record(bi,"$(PREFIX):DI1STATE")
>> >> {
>> >> field(DESC, "CURRENT TRANSDUCER")
>> >> field(SCAN, "1 second")
>> >> field(INP, "$(PREFIX):DISTATE.B1 PP")
>> >> field(OSV, "MAJOR")
>> >> field(ZSV, "NO_ALARM")
>> >> field(ONAM,"FAULT")
>> >> field(ZNAM, "OK")
>> >> }
>> >> .......
>> >>
>> >> Thank you very much for your help.
>> >>
>> >>
>> >> Best regards
>> >> Geyang 2008-10-15
>> >>
>> >>
>> >>
>> >
>>
>> = = = = = = = = = = = = = = = = = = = =
>>
>>
>> Best regards
>> Geyang 2008-10-15
>>
>>
>>
>>
>
[广告] 金秋最关注楼盘-房不胜房
- Navigate by Date:
- Prev:
Re: a question about mbbiDirect and fanout Ralph Lange
- Next:
Re: CA client application Benjamin Franksen
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
<2008>
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
- Navigate by Thread:
- Prev:
Re: a question about mbbiDirect and fanout Ralph Lange
- Next:
CA client application M.Babai
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
<2008>
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025