1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 <2011> 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 <2011> 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: StreamDevice/ASYN connection to a Telnet port |
From: | Maren Purves <[email protected]> |
To: | John Dobbins <[email protected]> |
Cc: | EPICS Tech-Talk <[email protected]> |
Date: | Wed, 02 Feb 2011 12:53:05 -1000 |
John/Dirk, does StreamDevice/ASYN have or allow a custom read function like drvAscii does? I have one for our dust monitor that turns 3 lines of reply (which are spaced out in time) and way too long for drvAscii into something that is one line of less than 80 characters. Wondering, Maren John Dobbins wrote:
Dirk,As it turns out this device really is sending one character per network packet. The device is a new version of the Gamma/Digitel Small Pump Controller which has an optional ethernet interface. The ethernet interface has other problems, e.g. one can crash the controller (turning of the pump H.V.) by overloading it with data requests. Gamma tells me they are working on improving the ethernet interface. For now I as using the RS-232 interface for this device which operates without problem.Thanks, John Dobbins On 2/2/2011 10:30 AM, Dirk Zimoch wrote:Hi John, StreamDevice normally reads first a single byte and then the rest in chunks of up to 63 bytes. The reason is that the first byte uses a different timeout (ReplyTimeout) than the others (ReadTimeout). The rest is fetched in 63 bytes chunks because I use an internal buffer of 64 bytes and want to be able to add a null byte at the end to avoid problems with some debug output. So the first "read 1" is normal. What surprises me are the other lines. When you switch on debugging in StreamDevice (var streamDebug 1), what do you see? Dirk John Dobbins wrote:Dear All,I am connecting to a Gamma Vacuum SPCe ion pump power supply. This device has an ethernet port which accepts telnet connections.I set up StremDevice to communicate with it on port 23, I have asyn Trace Masks set as follows: asynSetTraceMask("SPCe",-1,0x09) asynSetTraceIOMask("SPCe",-1,0x2I have a problem in that the response string , which I expect to look like "OK 00 7.90E-13 TORR"appears like this: epics> 2011/01/17 16:14:55.995 172.18.32.21:23 write 7 spc 0B\r 2011/01/17 16:14:56.475 172.18.32.21:23 read 1 O 2011/01/17 16:14:56.475 172.18.32.21:23 read 1 K 2011/01/17 16:14:56.475 172.18.32.21:23 read 1 2011/01/17 16:14:56.475 172.18.32.21:23 read 1 0 2011/01/17 16:14:56.475 172.18.32.21:23 read 1 0 2011/01/17 16:14:56.476 172.18.32.21:23 read 1 2011/01/17 16:14:56.476 172.18.32.21:23 read 1 7 2011/01/17 16:14:56.476 172.18.32.21:23 read 1 . 2011/01/17 16:14:56.476 172.18.32.21:23 read 1 9 2011/01/17 16:14:56.477 172.18.32.21:23 read 1 0 2011/01/17 16:14:56.477 172.18.32.21:23 read 1 E 2011/01/17 16:14:56.477 172.18.32.21:23 read 1 - 2011/01/17 16:14:56.477 172.18.32.21:23 read 1 1 2011/01/17 16:14:56.478 172.18.32.21:23 read 1 3 2011/01/17 16:14:56.478 172.18.32.21:23 read 1 2011/01/17 16:14:56.478 172.18.32.21:23 read 1 T 2011/01/17 16:14:56.478 172.18.32.21:23 read 1 O 2011/01/17 16:14:56.478 172.18.32.21:23 read 1 R 2011/01/17 16:14:56.479 172.18.32.21:23 read 1 R 2011/01/17 16:14:56.479 172.18.32.21:23 read 1 \r Can someone tell me what is going on here? Regards and thanks, John Dobbins Cornell University Lab for Elementary Particle Physics