Anne,
Hopefully you will receive this message via tech-talk because when I tried to send to your e-mail address it was blocked by the Argonne security:
****************************
honeypot-prod0.anl.gov rejected your message to the following e-mail addresses:
Anne M. ([email protected])
honeypot-prod0.anl.gov gave this error:
<carsmail2.cars.aps.anl.gov[164.54.162.47]>: Client host rejected: Destination domain blacklisted. Contact [email protected] for details.
Your message wasn't delivered due to a permission or security issue. It may have been rejected by a moderator, the address may only accept e-mail from certain senders, or another restriction may be preventing delivery.
****************************
If you think your domain should not be blocked we can ask Argonne to look into this.
Mark
________________________________________
From: [email protected] [[email protected]] on behalf of Mark Rivers [[email protected]]
Sent: Friday, April 08, 2016 7:18 AM
To: Anne M.; [email protected]
Subject: RE: modbus TCP command not found
I just tried it and it worked OK for me.
I think you may just be running it incorrectly. Here is how to do it:
cd to modbus/iocBoot/iocTest.
type this command:
../../bin/linux-x86/modbusApp sim3.cmd
That should work, the testModbusSyncIOConfigure should be recognized at that point.
You may get a number of error messages like this if you don't have a Modbus device or simulator that it can connect to.
2016/04/08 07:16:29.631 drvModbusAsyn::doModbusIO port A0_Out_Word error calling writeRead, error=asynManager::queueLockPort queueRequest failed: port sim1 not connected, nwrite=0/6, nread=0
Mark
________________________________
From: [email protected] [[email protected]] on behalf of Anne M. [[email protected]]
Sent: Friday, April 08, 2016 6:21 AM
To: [email protected]
Subject: modbus TCP command not found
Hello!
I am having some problems with my epics program...
I am currently working with modbus TCP (https://github.com/epics-modules/modbus/), so when trying to run the modbus example I get the following error:
"sim3.cmd line 40: Command testModbusSyncIOConfigure not found."
- To try yourself: What I am doing is that with the bin generated with the makefile avaliable at "/modbus/bin/linux-x86/modbusApp" I run sim3.cdm avaliable "/modbus/iocBoot/sim3.cmd", like:
$ ./modbusApp sim3.cmd
- What I think it is happening: at the source files "/modbus/modbusApp/src" there is a CC program that is the test I want to try. In testModbusSyncIO.cpp the function is defined so later sim3.cmd calls it with its arguments. This is what I want to do in my program, I just cant make the example to work.
Can someone help me? :)
--
[https://docs.google.com/uc?export=download&id=0B-JomN4-F_XybUpRdEU2cmFtMFk&revid=0B-JomN4-F_XybWFHMEcrd3llaHc5Zm0yN0dNZk1SdytxbktnPQ]<http://sevensols.com/>
Anne M. Munoz Perez
Software Development / Engineering
[email protected]<mailto:[email protected]>
[https://docs.google.com/uc?export=download&id=0B-JomN4-F_XyUFVsMEQ2UGlybjg&revid=0B-JomN4-F_XyVzE2ZXZPdi9NM1pnRDdEMHZSUXRqK2k0dU80PQ]<http://es.linkedin.com/in/anne-munoz-3118b79b> [https://docs.google.com/uc?export=download&id=0B-JomN4-F_XyZGc3STRVM2w2N28&revid=0B-JomN4-F_XydHMzQTkybWxOclZxVmF4ZWZNbmx0NEJXVWEwPQ] <http://twitter.com/petramika>
- References:
- modbus TCP command not found Anne M.
- RE: modbus TCP command not found Mark Rivers
- Navigate by Date:
- Prev:
RE: modbus TCP command not found Mark Rivers
- Next:
RE: how can make the MEDM and how can use the MEDM!!! Very difficult. Please, help me Arnold, Ned D.
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
<2016>
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
RE: modbus TCP command not found Mark Rivers
- Next:
Recommendation on a PCIe ADC board Vasquez Stanescu, Jesus A
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
<2016>
2017
2018
2019
2020
2021
2022
2023
2024