1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: Interrupt problem. |
From: | "Johnson, Andrew N. via Tech-talk" <tech-talk at aps.anl.gov> |
To: | Francisco Ramos <framoslandaeta at gmail.com> |
Cc: | EPICS tech-talk <tech-talk at aps.anl.gov> |
Date: | Wed, 26 Jan 2022 02:41:50 +0000 |
On Jan 25, 2022, at 1:43 PM, Francisco Ramos <framoslandaeta at gmail.com> wrote:
So it sounds like the vector 32 is your system clock tick, and calling BSP_disconnect_clock_handler() looks to be the wrong thing to do (it is disconnecting the handler, but isn't disabling the periodic tick interrupt first).
You would need to ask the RTEMS experts if it’s possible and how to replace the internal clock tick handler with your own dynamically at runtime like that, which is what you’re apparently doing there.
- Andrew
--