1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: Streamdevice reads weird 1 byte null data |
From: | Ralph Lange via Tech-talk <tech-talk at aps.anl.gov> |
To: | EPICS Tech Talk <tech-talk at aps.anl.gov> |
Date: | Wed, 20 Sep 2023 09:40:40 +0200 |
When not done correctly, 2-wire RS485 is prone to "echos" of the command you
send. A correctly made transceiver should disable its input while sending, but I
have had problems with newer MOXA DA-662 (but not older ones) re-enabling the
receiver too early. If MOXA uses the same chip in your nport 6650, it may be
unsuitable for 2-wire mode. You may want to try with a serial server from
another vendor.