1994  1995  <19961997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  <19961997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: IP-Octal 432 and 485 pinouts
From: [email protected] (Tim Mooney)
To: [email protected], [email protected], [email protected]
Date: Wed, 20 Mar 1996 18:01:17 -0600
re...,

> I have bought several Greenspring IP-Octal 432 and 485 units with the
> Engineering Kits.  In looking through the documentation I don't see any
> description of the pinouts or jumpers on the Distribution Panel.  Are these
> documented anywhere?

The rack-mountable distribution panel that connects two octal-serial IP's to
16 DB-9 connectors (GreenSpring calls this the "XM-Octal I/O".  Is this what
you mean?) has the following pinout:

DB-9	RS-232	RS-422	RS-485	RS-423
pin	signal	signal	signal	signal
--------------------------------------
1	-	-	-	-
2	RX	TX+	DX-	RX
3	TX	TX-	DX+	TX
4	-	-	-	-
5	GND	GND	GND	GND
6	-	-	-	-
7	RTS	RX-	-	RTS
8	CTS	RX+	-	CTS
9	-	-	-	-

We'll have this on our Web pages pretty soon.

Tim


Navigate by Date:
Prev: sch2edif query Sean Prior
Next: Re: sch2edif query Marti Pi i Puig
Index: 1994  1995  <19961997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: IP-Octal 432 and 485 pinouts Mark Rivers
Next: Flaw in ezca timeouts Guy Jennings
Index: 1994  1995  <19961997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024