1994 1995 1996 1997 <1998> 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 | Index | 1994 1995 1996 1997 <1998> 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: Xycom 566 waveform |
From: | Bob Dalesio <[email protected]> |
To: | "Garrett D. Rinehart" <[email protected]> |
Cc: | [email protected] |
Date: | Fri, 19 Jun 1998 07:02:08 -0600 (MDT) |
After reading back through the code - it seems to me that the Xy566 waveform is set up to use an external trigger for each sample. This was accomplished with an 085 board that was designed at LANL (as I recall). To use the 566 as an array you would need to: 1) 566 short address space to 9000 2) 566 standard IO space to 80000 3) remove the need for an 085 (Number 3 may be as easy as removing the need in the xy566_init routine or may require setting something different in the init sequence so that instead of an external trigger for each value - it uses only one trigger to reset it - I could look into this further at a later time.) Bob