I am having problems with a Hytec VSD2992 CAMAC Serial Highway Driver. I am
using the LANL driver software.
The module works fine when the CAMAC link is working. If I momentarily
disconnect the link or otherwise try to generate link errors, the MVME177
hangs with its VMEbus LED stuck on. Channel Access disconnects and I can't
access the '177 from the local console. The 2992 LEDS show errors and LAMs.
Reconnecting the CAMAC link back doesn't help, the only way to resume
operation is to reboot the '177.
This is my 3rd 2992 and the first two never exhibit this problem. Hytec has
the problematic 2992 and claim "it works here (in the U.K.)". They are
claiming that I must be configuring the 2992's registers to generate
interrupts , which are not being serviced properly.
1) Is the '177 hung or is it continually servicing a (high priority) VME
interrupt?
2) Is there a way to disable ISR's from the 2992 ?
3) How can I track what's going on in either the '177 or in the 2992
software driver.
-ps
- Navigate by Date:
- Prev:
fix for a VXI addressing bugs in dbStaticLib Rozelle Wright
- Next:
R3.13.0.beta12 + PPC MV2306 + VxWorks 5.3.1 (Tornado 1.0.1) + Solaris 2.6 Martí Pi
- Index:
1994
1995
1996
1997
<1998>
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
fix for a VXI addressing bugs in dbStaticLib Rozelle Wright
- Next:
RE: CAMAC 2992 hangs vmebus Eric Bjorklund, NPSM
- Index:
1994
1995
1996
1997
<1998>
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024