As Peregrine pointed out in his posting and as several people have
pointed out privately to me, you should make sure that the scan periods
are integral numbers of VxWorks ticks. If not, you will not get the
period that you expected (it will be rounded down).
We run with a VxWorks system clock frequency of 200Hz.
William