1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 <2008> 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 <2008> 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Light Source BPM Electronics |
From: | "Elder Matias" <[email protected]> |
To: | <[email protected]> |
Cc: | Song Hu <[email protected]> |
Date: | Tue, 2 Sep 2008 21:10:30 -0600 |
A little off topic but I thought I would toss this out there in case it saves someone a bit of time. We use the Bergoz BPM electronics for orbit correction on our ring, but have been considering changing a few of our BPM system over to Libera Brilliance for the single bunch and tune measurement capability. Prior to doing this we spent some time characterizing the units.
About a week or two ago Song finished the report on the Libera Brilliance it is available at:
http://www.lightsource.ca/operations/pdf/7.5.39.67.Rev.0-Libera_Brilliance_Evaluation-Hu.pdf
The Libera Electron study is available at:
http://www.lightsource.ca/operations/pdf/7.5.39.60.Rev.0-Libera_Electron_Evaluation-Sewell.pdf
The Bergoz BPM study is available at:
http://www.lightsource.ca/operations/pdf/7.2.38.5.Rev0-BPM_Test_Report-Stavness.pdf
Elder