EPICS Home

Experimental Physics and Industrial Control System


 
1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: write failure occuring in writeScanRecInProgress function (after writing header) in saveData.c (sscan-2-6-6 module)
From: Jay Steele <[email protected]>
To: "[email protected]" <[email protected]>
Date: Tue, 2 Nov 2010 15:01:02 -0700
Hi EPICS tech-talk,
     I'm having a problem executing my first simple 1D scan here at XRadia. I set up the scan as simply as I could - with one positioner and one data source (SIS 3820 board with input to channel #9 from a signal generator). I am using TPMAC records (e.g., bkgfix1pcs_scanrec_v3.db and AssyGeneric_scanrec_v3.db to set up records) for the positioner. I verified that the SIS 3820 record works to count the pulses from the signal generator, and also that I can move the motor simply by setting 21:D3:BNP:XY:PX:RqsPos. I start the scan and the vxWorks terminal reports the following (with debug_saveData =10, debug_saveDataMsg=10) and keeps trying to write to the scan file without success. Attached is a screen shot of the MEDM interface for the scan. I'm using epics-3-14-11 with VxWorks and compiling with cygwin on windows-x86.
 
saveDataTask: MSG_SCAN_PXNV, ix=0, val=2.000000
21:D3:BNP:scan1 MSG_SCAN_PXNV(2)= 0.000000
saveDataTask: MSG_SCAN_PXNV, ix=0, val=0.000000
21:D3:BNP:scan1 MSG_SCAN_PXNV(0)= 0.000000
saveDataTask: MSG_DESC, val=
MSG_DESC()= 0.000000
 nb_scan_running=1
saveDataTask: MSG_SCAN_DATA, val=0
proc_scan_data(21:D3:BNP:scan1):entry:pmsg->val=0
scan started: 21:D3:BNP:scan1
Checking number of valid positioner
Checking number of valid detector
Checking number of valid trigger
Outermost scan
proc_scan_data(21:D3:BNP:scan1):New file
saveData: stat returned -1 for filename '/data/Nov-1-2010/test_0008.mda'; errno=
3145730
saveData:writeScanRecInProgress: Opening file '/data/Nov-1-2010/test_0008.mda'
saveData:writeScanRecInProgress: Writing file header
saveData:writeScanRecInProgress: scan_dim=1
saveData:writeScanRecInProgress:(21:D3:BNP:scan1) scan_dim=1, dims_offset=0
saveData:writeScanRecInProgress: File Header written
saveData:writeScanRecInProgress: Writing per-scan header
saveData:writeScanRecInProgress: Save scan info
saveData:writeScanRecInProgress: Pos[0] info
saveData:writeScanRecInProgress: Det[0] info
saveData:writeScanRecInProgress: Trg[0] info
saveData:writeScanRecInProgress: Allocate space for Pos[0]
saveData:writeScanRecInProgress: Allocate space for Det[0]
saveData:writeScanRecInProgress:(21:D3:BNP:scan1) scan_dim=1, dims_offset=0
    
     From this output, I tracked the problem down to a write failure in the writeScanRecInProgress function in saveData.c. This occurs after the function writes out the file header and allocates space for Pos[0] and Det[0].
 
     I'm confused why there would be a write failure at this point. Can anybody determine from this problem what might be wrong with my setup to cause this problem?
 
Thanks,
Jay Steele
XRadia Corporation


The information in this email, including any attachments, is confidential and intended only for the recipient(s) listed. Any use of this email for any other purpose is prohibited. If you have received this email in error, please notify me immediately by reply email, delete this email, and do not disclose its contents to anyone.

Attachment: full scan pict.JPG
Description: full scan pict.JPG


Replies:
RE: write failure occuring in writeScanRecInProgress function (afterwriting header) in saveData.c (sscan-2-6-6 module) Mark Rivers
Re: write failure occuring in writeScanRecInProgress function (after writing header) in saveData.c (sscan-2-6-6 module) Tim Mooney

Navigate by Date:
Prev: Re: monitors received out of order Ralph Lange
Next: Re: monitors received out of order Ben Franksen
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Open group leader position for DAQ & controls at PSI, Switzerland Luedeke Andreas
Next: RE: write failure occuring in writeScanRecInProgress function (afterwriting header) in saveData.c (sscan-2-6-6 module) Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024