The database that's generated by TDCT:
(look at the FLNK field of the first record)
--------
#= database generated by tdct V2.14.4
#= (mode: Capfast compatibility)
record(stringin,"$(top)subschematic:si") {
field(DESC,"string input record")
field(SCAN,"Passive")
field(PINI,"NO")
field(PHAS,"0")
field(EVNT,"0")
field(DTYP,"Soft Channel")
field(DISV,"1")
field(SDIS,"0.000000000000000e+00")
field(DISS,"NO_ALARM")
field(PRIO,"LOW")
field(FLNK,"$(top)subschematic:subschematic:subschematic:ao.VAL")
field(VAL,"string")
field(INP,"0.000000000000000e+00")
field(SIOL,"0.000000000000000e+00")
field(SIML,"0.000000000000000e+00")
field(SIMS,"NO_ALARM")
}
record(ao,"$(top)subschematic:ao") {
field(DESC,"analog output record")
field(SCAN,"Passive")
field(PINI,"NO")
field(PHAS,"0")
field(EVNT,"0")
field(DTYP,"Soft Channel")
field(DISV,"1")
field(SDIS,"0.000000000000000e+00")
field(DISS,"NO_ALARM")
field(PRIO,"LOW")
field(FLNK,"0.000000000000000e+00")
field(OUT,"0.000000000000000e+00")
field(OROC,"0.0000000e+00")
field(DOL,"0.000000000000000e+00")
field(OMSL,"supervisory")
field(OIF,"Full")
field(PREC,"0")
field(LINR,"NO CONVERSION")
field(EGUF,"0.0000000e+00")
field(EGUL,"0.0000000e+00")
field(EGU,"volts")
field(DRVH,"0.0000000e+00")
field(DRVL,"0.0000000e+00")
field(HOPR,"0.0000000e+00")
field(LOPR,"0.0000000e+00")
field(HIHI,"0.0000000e+00")
field(LOLO,"0.0000000e+00")
field(HIGH,"0.0000000e+00")
field(LOW,"0.0000000e+00")
field(HHSV,"NO_ALARM")
field(LLSV,"NO_ALARM")
field(HSV,"NO_ALARM")
field(LSV,"NO_ALARM")
field(HYST,"0.000000000000000e+00")
field(ADEL,"0.000000000000000e+00")
field(MDEL,"0.000000000000000e+00")
field(SIOL,"0.000000000000000e+00")
field(SIML,"0.000000000000000e+00")
field(SIMS,"NO_ALARM")
field(IVOA,"Continue normally")
field(IVOV,"0.000000000000000e+00")
}
Is there a newer version of TDCT which fixes this?
Or might we have something configured wrong?
Thanks,
--
Mike Westfall
Control Systems Software Engineer