Experimental Physics and Industrial Control System
Subject: |
areaDetector ADProsilica dbJLinkDebug undefined reference |
From: |
Heinz Junkes via Tech-talk <[email protected]> |
To: |
tech-talk <[email protected]> |
Date: |
Sun, 14 Jul 2019 17:50:47 +0200 |
areadetector 3-6
ADProsilica Release 2-5
/usr/bin/g++ -o prosilicaApp -L/home/epics/EPICS/SUPPORT/areaDetector/ADProsilica/lib/linux-x86_64 -L/home/epics/EPICS/SUPPORT/areaDetector/ADProsilica/iocs/prosilicaIOC/lib/linux-x86_64 -L/home/epics/EPICS/SUPPORT/areaDetector/ADCore/lib/linux-x86_64 -L/home/epics/EPICS/SUPPORT/areaDetector/ADSupport/lib/linux-x86_64 -L/home/epics/EPICS/SUPPORT/asyn/lib/linux-x86_64 -L/home/epics/EPICS/base-7.0.2/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/SUPPORT/areaDetector/ADProsilica/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/SUPPORT/areaDetector/ADProsilica/iocs/prosilicaIOC/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/SUPPORT/areaDetector/ADCore/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/SUPPORT/areaDetector/ADSupport/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/SUPPORT/asyn/lib/linux-x86_64 -Wl,-rpath,/home/epics/EPICS/base-7.0.2/lib/linux-x86_64 -rdynamic -m64 prosilicaApp_registerRecordDeviceDriver.o prosilicaAppMain.o -lprosilica -lPvAPI -lNDPlugin -lADBase -lqsrv -lntndArrayConverter -lnt -lpvDatabase -lpvAccessIOC -lpvAccessCA -lpvAccess -lpvData -lnetCDF -lMagick++ -lcoders -lMagick -ljbig -ljp2 -lbzlib -lpng -lwebp -llcms -lttf -lwmf -lfilters -ltiff -lxml2 -lNeXus -lhdf5 -lhdf5_hl -lbitshuffle -lblosc -lszip -lzlib -ljpeg -lasyn -lCom -lX11 -lXext
/usr/bin/ld: prosilicaApp_registerRecordDeviceDriver.o: undefined reference to symbol ‘pvar_int_dbJLinkDebug'
//home/epics/EPICS/base-7.0.2/lib/linux-x86_64/libdbCore.so.3.17.2: error adding symbols: DSO missing from command line
collect2: error: ld returned 1 exit status
I have only selected proSilica support.
What am I doing wrong?
Danke, Heinz
------------------------------------------------------------------------------
Fritz-Haber-Institut | Phone: (+49 30) 8413-4270
Heinz Junkes | Fax (G3+G4): (+49 30) 8413-5900
Faradayweg 4-6 |
D - 14195 Berlin | E-Mail: [email protected]
------------------------------------------------------------------------------
Attachment:
smime.p7s
Description: S/MIME cryptographic signature
- Replies:
- Re: areaDetector ADProsilica dbJLinkDebug undefined reference Michael Davidsaver via Tech-talk
- Navigate by Date:
- Prev:
Re: [EXTERNAL] updating ADAndor from RHEL6 to RHEL7 Hinko Kocevar via Tech-talk
- Next:
Re: areaDetector ADProsilica dbJLinkDebug undefined reference Michael Davidsaver via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
<2019>
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: any support for ISEG NHQ 204M power supply Ralph Lange via Tech-talk
- Next:
Re: areaDetector ADProsilica dbJLinkDebug undefined reference Michael Davidsaver via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
<2019>
2020
2021
2022
2023
2024