- Create a new directory to hold the application source and
then `cd' to that directory.
- Run the
makeBaseApp.pl
program to create the example application:
makeBaseApp.pl -t example test
makeBaseApp.pl -i -t example -a RTEMS-mvme2100 test
If you get complaints about not being able to run these commands you've
probably forgotten to put the `bin'
directory created in the previous section on your shell executable search path.
The `test
' in the two makeBaseApp.pl
commands can be replaced with whatever name you
want to give your example application.
The `RTEMS-mvme2100
' can be replaced with whatever target architecture you
plan to use to run the example application.
- Build the example application by running
make
The application build process creates db and dbd directories
in the top-level application directory and
produces a set of IOC shell commands in
the st.cmd file in the iocBoot/ioctest directory. If you chose
an application name different than test in the previous step, the
directory name will change accordingly.
These directories and their contents
must be copied to your TFTP/NFS server. The actual location depends upon
the remote file access technique being used as described
in the following section.
Run the example application on an RTEMS IOC
Everything's now ready to go. The only item left is arranging some
way of loading the RTEMS/EPICS application executable image into the IOC.
There are many ways of doing this (floppy disks, PROM images, etc.), but
I find using a BOOTP/DHCP/TFTP
server to be the most convenient. The remainder of this section describes
how I load executables into my RTEMS-mvme2100 and RTEMS-pc386 IOCs.
If you're running a different type of IOC you'll have to figure out the
required steps on your own. The RTEMS documentation may provide the
required information since an EPICS IOC application is an RTEMS application
like any other.
Some RTEMS board-support packages require an NTP server on the network.
If such an IOC doesn't receive a time-synchronization packet from an NTP
server the IOC time will be set to 00:00:00, January 1, 2001.
If you're using BOOTP/DHCP to provide network configuration information
to your IOC you should use DHCP site-specific option 129 to specify
the path to the IOC startup script.
If you're using PPCBUG you should set the NIOT `Argument File Name' parameter
to the IOC startup script path.
If you're using NFS for remote file access the EPICS initialization uses the
startup script pathname to determine the parameters for the initial NFS mount.
If the startup script pathname begins with a `/
' the first component
of the pathname is used as both the server path and the local mount point.
If the startup script pathname does not begin with a `/
' the
first component of the pathname is used as the local mount point and the
server path is ``/tftpboot/
'' followed by the first component of
the pathname. This allows the NFS and TFTP clients to have a similar
view of the remote filesystem.
If you're using TFTP for remote file access
the RTEMS startup code
first changes directories to /epics/hostname/ within
the TFTP server, where hostname is the Internet host name of the IOC.
The startup code then reads IOC shell commands from the st.cmd script
in that directory.
The name (st.cmd) and location of the startup script are fixed from the IOCs point of
view so it must be installed in the corresponding location on the TFTP server.
Many sites run the TFTP server with an option which changes its root directory.
On this type of system you'll have to copy the startup script to the
/epics/hostname/ directory within the TFTP server's root
directory. On a system whose TFTP server runs with its root
directory set to /tftpboot the startup script for the IOC
whose name is norumx1 would be placed in
/tftpboot/epics/norumx1/st.cmd
The application build process creates db and dbd directories
in the top-level application directory. These directories and their contents
must be copied to the IOC's directory on the TFTP server. For the
example described above the
command to install the files for the norumx1 IOC is
cp -r db dbd /tftpboot/epics/norumx1
- Use the PPCBUG ENV command to set the `Network PReP-Boot Mode Enable'
parameter to `Y'.
- Use the PPCBUG NIOT command to set the network parameters. Here are the
parameters for a test IOC I use:
Controller LUN =00
Device LUN =00
Node Control Memory Address =FFE10000
Client IP Address =www.xxx.yyy.8
Server IP Address =www.xxx.yyy.131
Subnet IP Address Mask =255.255.252.0
Broadcast IP Address =192.168.11.255
Gateway IP Address =0.0.0.0
Boot File Name ("NULL" for None) =/epics/test/bin/RTEMS-mvme2100/example.boot
Argument File Name ("NULL" for None) =www.xxx.yyy.98:/home/epics:test/iocBoot/iocexample/st.cmd
Boot File Load Address =001F0000
Boot File Execution Address =001F0000
Boot File Execution Delay =00000000
Boot File Length =00000000
Boot File Byte Offset =00000000
BOOTP/RARP Request Retry =00
TFTP/ARP Request Retry =00
Trace Character Buffer Address =00000000
BOOTP/RARP Request Control: Always/When-Needed (A/W)=W
BOOTP/RARP Reply Update Control: Yes/No (Y/N) =Y
- Set up your TFTP/NFS servers. PPCBUG uses TFTP
to load the executable image then the EPICS initialization uses
NFS to read the EPICS startup script (the `Argument File Name' in the NIOT
parameters).
I set the TFTP server root to /tftpboot and arrange for the NFS server to
export /tftpboot/epics to the IOCs. This arrangement lets me simply copy the
application tree, beginning at the
<top>
directory to the TFTP/NFS server area.
Motorola Processors Using MOTLOAD
The following `Global Environment Variables' are used. These are set using
the MOTLOAD gevEdit command.
- mot-script-boot
- These commands are run by MOTLOAD when the board is booted. A typical example is shown below:
tftpGet -cww.ww.ww.ww -sxx.xx.xx.xxx -myy.yy.yy.yy -d/dev/enet0 -fpath
netShut
go
where ww.ww.ww.ww is the IP number of the client (VME card),
xx.xx.xx.xx is the IP number of the TFTP server,
yy.yy.yy.yy is the IP subnet mask, and
path is the path to the executable image file on the TFTP server.
The standard MOTLOAD download buffer may be too small to hold your application. If this is the
case you can call malloc to allocate a larger buffer and then use the -a option to pass the address of this buffer to the tftpGet and go commands:
dla=malloc 0x280000
tftpGet -cww.ww.ww.ww -sxx.xx.xx.xxx -myy.yy.yy.yy -d/dev/enet0 -fpath -adla
netShut
go -adla
- mot-/dev/enet0-cipa
- The client (VME card) IP address. If this variable is not set the client address is
set to the value of the `-c' argument in the mot-script-boot variable.
- mot-/dev/enet0-sipa
- The server IP address. If this variable is not set the server address is
set to the value of the `-s' argument in the mot-script-boot variable.
- mot-/dev/enet0-gipa
- The gateway IP address. If this variable is not set the gateway IP address is
set to the value of the `-g' argument in the mot-script-boot variable.
- mot-/dev/enet0-snma
- The subnet mask. If this variable is not set the subnet mask is
set to the value of the `-m' argument in the mot-script-boot variable.
- mot-/dev/enet0-file
- The name of the executable image. If this variable is not set the name is
set to the value of the `-f' argument in the mot-script-boot variable.
The name is passed as the `argv[0]' to the main() function.
- rtems-dns-server
- The domain name server IP address. If this variable is not set the server address as described above is used.
- rtems-dns-domainname
- The domain name. If this variable is not set the value compiled into the executable image is used.
- rtems-client-name
- The client host name. If this variable is not set the client address as described above is used.
- epics-script
- The path to the IOC startup script on the TFTP or NFS server.
The value can be a simple path or be of the form
nfsServer:nfsExport:nfsPath.
The nfsExport component is the directory exported from the NFS server and is also used as the local mount point and as a prefix to nfsPath.
- epics-nfsmount
- If set, this variable should be of the form
nfsServer:nfsExport:nfsMount.
The nfsExport component is the directory exported from the NFS server
and the nfsMount is the local mount point.
- epics-ntpserver
- The NTP server IP address. If this variable is not set the server address as described above is used.
- epics-tz
- Set the value of the TZ environment variable.
This is useful for handling daylight-savings-time changes. A value of
CST6CDT5,M3.2.0,M11.1.0 is appropriate for Chicago in 2007 and perhaps subsequent years.
- Install an EtherBoot bootstrap PROM image obtained from
the `ROM-o-matic' server (http://www.rom-o-matic.net/) on the IOC
network interface cards.
- Set up your BOOTP/DHCP server to provide the network configuration
parameters to the IOC.
- The TFTP and NFS servers can be configured as noted above.
Use the bootstrap setenv command to set the EPICS and network
configuration parameters:
IPADDR0=www.xxx.yyy.27
HOSTNAME=ioccoldfire
BOOTFILE=epics/ucdimm/bin/RTEMS-uC5282/ucdimm.boot
NAMESERVER=www.xxx.yyy.167
NETMASK=255.255.252.0
CMDLINE=epics/i2c/iocBoot/ioci2c/st.cmd
SERVER=www.xxx.yyy.161
NFSMOUNT=106.74@nfssrv:/export/nfssrv:/home/nfssrv
The environment variables used by the EPICS startup code are:
- IPADDR0
- The client (Coldfire processor) IP address.
- HOSTNAME
- The client host name.
- SERVER
- The server IP address. If this variable is not set the specific server
addressses as described below must be set.
- GATEWAY
- The gateway IP address. If this variable is not set the Coldfire will be
able to communicate only with hosts on its local network.
- NETMASK
- The subnet mask.
- BOOTFILE
- The name of the executable image.
The name is passed as the `argv[0]' to the main() function.
- NTPSERVER
- The NTP server IP address. If this variable is not set the server address as described above is used.
- NAMESERVER
- The domain name server IP address. If this variable is not set the server address as described above is used.
- DOMAIN
- The domain name. If this variable is not set the value compiled into the executable image is used.
- CMDLINE
- The path to the IOC startup script on the TFTP or NFS server.
The value can be a simple path or be of the form
nfsServer:nfsExport:nfsPath.
The nfsExport component is the directory exported from the NFS server and is also used as the local mount point and as a prefix to nfsPath.
- NFSMOUNT
- If set, this variable should be of the form
nfsServer:nfsExport:nfsMount.
The nfsExport component is the directory exported from the NFS server
and the nfsMount is the local mount point.
- TZ
- Set the value of the TZ environment variable.
This is useful for handling daylight-savings-time changes. A value of
CST6CDT5,M3.2.0,M11.1.0 is appropriate for Chicago in 2007 and perhaps subsequent years.
The uCDIMM ColdFire 5282 module is distributed with two types of bootstrap ROMs. One type provides a TFTP server and the other provides a TFTP client.
The steps required to boot an EPICS application differ depending on the the bootstrap type.
Use the bootstrap tftp command to load the IOC application image
(which may include a tar image of the in-memory filesystem contents in which case the CMDLINE will likely look something like /st.cmd and the NFSMOUNT need not be present).
You'll need to run a TFTP client on your host machine to transfer the
file. An example using curl is:
curl -T bin/RTEMS-uC5282/example.boot tftp://192.168.1.93
where 192.168.1.93 is the IP address of the ColdFire target.
Use the bootstrap goram command to start the application or the
program command to burn the image into the on-board flash memory. In
the latter case you may want to also use the setenv command to set the
AUTOBOOT environment variable.
The bootstrap procedure in this case is similar to that for the Motorola VME processors in section 4.1.4.
The cexp package can be used to
incrementally load your application components.