Hi all!
I'm yongnian from SSRF(Shanghai Synchrotron Radiation Facility).To use softGlue,we bought 2 sets of Acromag's products, including AVME9670 + IP-EP201 + TRANS-200 + 5028-378 Termination Panel.
We tried to compiled a softGlue application in EPICS according to the guide http://www.aps.anl.gov/bcda/synApps/softGlue/softGlueDoc.html.
According to the guide,we finished ipac,asyn,busy and softGlue modules.
When we loading the application in MVME5500 and vxWorks, it had an error such as:
initIP_EP200_FPGA(0,0,"$(SOFTGLUE/softGlueApp/Db/SoftGlue_2_2_1ID_Vgate_0_1.hex)
initIP_EP200_FPGA:bad carrier or slot
value = -1 = 0xffffffff
It seemed that the IP-carrier number or the IP-slot number is wrong. In our case,we use only one carrier board AVME9670 with only one IP card IP-EP201.Is our parameters right?
Thank you very much for giving us guide!
yours yongnian
- References:
- Please help us with some error when running a softGlue application! 周永年
- Navigate by Date:
- Prev:
MsAceess Database and CSS connectivity Ganesh Jangir
- Next:
Re: caget can't connect to soft ioc on host with multiple NICs Dirk Zimoch
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
<2013>
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Please help us with some error when running a softGlue application! 周永年
- Next:
MsAceess Database and CSS connectivity Ganesh Jangir
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
<2013>
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024