1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: [EXTERNAL] Bus errors accessing VME with base 7.0.6.1 and latest synApps modules |
From: | "Hartman, Steven via Tech-talk" <tech-talk at aps.anl.gov> |
To: | Mark Rivers <rivers at cars.uchicago.edu> |
Cc: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Thu, 9 Jun 2022 20:58:18 +0000 |
Looking for an example with A16 access, I only found one, embedded in the first email of the thread . . . [Wed May 18 20:23:06 2022] VME Bus Error accessing A16: 0x300e . . . [Wed May 18 20:23:06 2022] 0x55d8aa0 (CAS-event): The task has been terminated because it triggered an exception that raised the signal 10. . . .
ioc13ida> tt 0x55d8aa0
. . . fr0 = -1 No obvious relation between -1.0 and 0xfbff300e, though. For the A32 access errors, the FR0 value appears to always match the bad address. On Jun 9, 2022, at 1:56 PM, Hartman, Steven via Tech-talk <tech-talk at aps.anl.gov> wrote: |