1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
<== Date ==> <== Thread ==>

Subject: Re: AlliedVision Manta G-235B
From: Mark Rivers via Tech-talk <tech-talk at aps.anl.gov>
To: EPICS Tech-Talk <tech-talk at aps.anl.gov>, Miroslaw Dach <mdach at lbl.gov>
Date: Sat, 4 Nov 2023 13:27:07 +0000
Hi Mirek,

The Manta G-145B uses the Sony ICX-285 CCD sensor.  It is 1388x1038 pixels and does 15 frames/s.
The Manta G-235B uses the Sony IMX-174 CMOS sensor.   It is 1936x1215 pixels and does 50 frames/s.  It is a much better sensor than the ICX-285 with more pixels, greater full well capacity, better sensitivity and higher speed.

I don't have experience with that camera, but I do have experience with that sensor in cameras from FLIR (formerly Point Grey).  I have extensively used these models:

GS3-U3-23S6M-C  This is a USB-3 version that does 163 frames/s 8-bit and 110 frames/s 12-bit. 

GS3-PGE-23S6M-C  This is a GigE version that does 48 frames/s 8-bit and 29 frames/s 12-bit. 

Any of these cameras should work fine.

If you go with the Allied Vision camera I recommend you switch from the ADProsilica driver to the ADVimba or ADAravis drivers.  ADProsilica is based on a very old SDK that is no longer supported.

Mark




From: Tech-talk <tech-talk-bounces at aps.anl.gov> on behalf of Miroslaw Dach via Tech-talk <tech-talk at aps.anl.gov>
Sent: Friday, November 3, 2023 1:49 AM
To: EPICS Tech-Talk <tech-talk at aps.anl.gov>
Subject: AlliedVision Manta G-235B
 
Hi folks,

We have been using in ALS the AlliedVision Manta G-145B cameras with areaDetector ADProsilica driver for several years .
The G-145B cameras are used to capture beam spot images in ALS.
This camera model is not produced any more so we are searching for an alternative.
The AlliedVision suggested an alternative model: Manta G-235B with similar specification. 
Do any of you have experience with  Manta G-235B cameras or other models which could be worth considering?

Our requirements are:
GigE standard
pixel size under: 10um x 10um
sensor size 2/3"  
update rate 10Hz
12 bits  CCD/CMOS
image size like:  1390x1038
triggerable with the external trigger
preferred:
24V power
C-Mount

Best Regards
Mirek


Replies:
Re: AlliedVision Manta G-235B Cobb, Tom (DLSLtd,RAL,LSCI) via Tech-talk
References:
AlliedVision Manta G-235B Miroslaw Dach via Tech-talk

Navigate by Date:
Prev: RE: Cannot do successful RS-232 communication with baud rates <2400 with VME and IP module Mark Rivers via Tech-talk
Next: ci-scripts 3.4.1 release: updates, improvements and fixes Ralph Lange via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
Navigate by Thread:
Prev: AlliedVision Manta G-235B Miroslaw Dach via Tech-talk
Next: Re: AlliedVision Manta G-235B Cobb, Tom (DLSLtd,RAL,LSCI) via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024