1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 <2005> 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 <2005> 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | RE: The later four ports of IP-Octal-232 could not work. |
From: | "Mark Rivers" <[email protected]> |
To: | "ligang" <[email protected]>, <[email protected]> |
Date: | Mon, 28 Mar 2005 07:23:35 -0600 |
Dear Li Gang, Is your VIPC616 the standard board, or do
you have the -01 option? I believe that the standard board does not
support one interrupt, which is used by the last slot (D). At the APS we
use the VIPC616_01, and I think it works fine with IP-Octal in any slot. You can convert a standard VIPC616 to the
-01 option yourself. You need to wire-wrap some pins, and replace 2 PAL
chips. Marty Smith at the APS can provide you with the details on how to
do this. Mark Rivers From: ligang
[mailto:[email protected]] Hi
Everyone; I am using the IP-Octal 232 and VIPC616
carrier board, with drvAscii/drvSerial/tyGSOctal. There are four slots(A ,B ,C ,D
) in one VIPC616 and eight ports(a ,b ,c ,d ,e ,f ,g ,h )
in each IP-Octal 232. The communication is ok between IP-Octal 232 and other
devices, when the IP-Octal 232 is put into slot A, or slot B ,or slot C of
VIPC616. When the IP-Octal 232 is put into slot D
of the VIPC616, The later ports(e ,f ,g ,h ) of the IP-Octal 232 doesn't work again,
however,the first four ports(a ,b ,c ,d ) of IP-Octal
232 work well. I have exchange several IP-Octal 232 and
VIPC616 respectively, the same errors will occur again. Is anybody could do help me? any adivce ia appreciated!
Thanks in advance. Li,Gang Accelerator
Control Group, Tel: +86-10-88235040 ext. 808 |