Here at Hytec we do an IP Card (the 8403) which can be coupled with
8913P Din Rail Breakout Box, this gives you 14 PT-100s for about 1200
euros (85 per channel). By changing the 8913P to 8913T the IP Card can
use thermocouples instead.
A possible solution for anyone after a VME / IP Carrier Solution.
EPICS drivers and software support provided free.
Darrell Nineham
Hytec Electronics Ltd.
Tel: +44 (0) 118 975 7770
Fax: +44 (0) 118 975 7566
Web: www.hytec-electronics.co.uk
++++++++++++++++++++++++++++++++++++++++++++
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom they are
addressed. If you have received this email in error, please notify the
sender immediately. The views expressed in the message are those of the
individual author and may not necessarily represent the views of Hytec
Electronics Ltd.
-----Original Message-----
From: Bernhard Kuner [mailto:[email protected]]
Sent: 20 January 2006 09:31
To: Josh Stein; [email protected]
Subject: Re: Cost effective solution for monitoring a large number of
temperatures
Here with BESSY we ar going to install an version of our ADA-Card that
offers in the VME-Bus version 32 temperature channels for PT100 sensors.
This Card is delivered by EuKontrol and is about 2500 EUR, that means 78
EUR/channel. We use here the 3HE-Version with 16 channels per card and
controlled via our embedded controler and the CAN-Bus. There is device
support for EPICS available. A good feature is that this card uses the
same long time stable integrating AD converter as all our ADA-Cards and
so it is best suited in noisy environment with long cables to the
sensor. I want to mention it because we had some trouble with that
before.
Regards
Bernhard Kuner
- References:
- Re: Cost effective solution for monitoring a large number of temperatures Bernhard Kuner
- Navigate by Date:
- Prev:
Re: Cost effective solution for monitoring a large number of temperatures Bernhard Kuner
- Next:
synApps workshop part 2 - 20-23 February Rees, NP (Nick)
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
<2006>
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: Cost effective solution for monitoring a large number of temperatures Bernhard Kuner
- Next:
RE: Cost effective solution for monitoring a large number of temperatures Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
<2006>
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024