1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 <2009> 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 <2009> 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | RE: Winsock errors |
From: | "Jeff Hill" <[email protected]> |
To: | "'Mark Clift'" <[email protected]>, <[email protected]> |
Date: | Fri, 24 Apr 2009 09:33:13 -0600 |
Hello Mark, Ø CAS:
Client accept error was "WINSOCK Error 10004" When the IOC core components were ported to other OS besides
vxWorks for EPICS R3.14 one task that was left unfinished was a well
orchestrated shutdown. Unfortunately, the only way to shutdown the original
R3.13 vxWorks IOC was to press the reset switch or remove power. That situation
isn’t really different in R3.14 except that now on Linux and Windows the
IOC is shutdown by abruptly terminating the IOC’s process. Many threads
in the system including the database processing, the CA server, device drivers,
actually nearly all of the threads in the IOC remain running when the IOC’s
process exits. The message you see are the last dying gasps from the CA server
threads when the WINSOCK shareable library is abruptly ripped out of memory. I am consolidating to only one server code, and one side effect
will be gracefully shutdown of the CA server – installed first into EPICS
R3.15. Jeff From:
[email protected] [mailto:[email protected]] On
Behalf Of Mark Clift Hello, I'm
building a basic IOC under windows by doing the following: makeBaseApp.pl
-t ioc <name> makeBaseApp.pl
-i -t ioc <name> Then
I build the ioc, and run it without databases. Upon exit I get the
following errors CAS: Client accept error was "WINSOCK Error 10004" or
CAS: Client accept error was "WINSOCK Error 10004" Has
anybody had this error, and know how to fix ? Thanks
heaps, Mark Clift. This message and any attachments may contain proprietary or
confidential information. If you are not the intended recipient or you received
the message in error, you must not use, copy or distribute the message. Please
notify the sender immediately and destroy the original message. Thank you. |