Experimental Physics and Industrial Control System
I am trying to use the "native" (NI-supplied) EPICS I/O Server support for LabVIEW
2009 without the LabVIEW Datalogging and Supervisory Control (DSC) module.
I followed the relevant download and installation instructions, as shown in this page:
http://zone.ni.com/devzone/cda/tut/p/id/10812
Its worth mentioning that step 5 as shown on that page (and the file
'epicsreadme.txt') is identical to Step 2. I assume this is an error and should in
fact state that a further software installation is to be done from the .msi file in
folder EPICS_LVSupp_90?
Anyway, having performed the installation and restarted the National Instruments
Variable Engine, I right-click on 'My Computer' target in a new Project window,
select 'New>I/O Server' from the shortcut menu, select 'EPICS Client' option (this
does appear) and finally click the 'Continue..' button.
A 'Configure EPICS Client I/O Server' dialog box should appear. But for me, nothing
happens at all after I click the 'Continue' button. so I cannot configure an EPICS
I/O Server.
I have repeated this installation now on 3 separate PCs, all behave the same. All
are running LabVIEW 2009 on Windows XP.
Has anyone succeeded in configuring an EPICS I/O Server for LabVIEW 2009 without the
Datalogging and Supervisory Control module?
Philip Taylor
===============================================================================
Philip Taylor email : [email protected]
Observatory Sciences Ltd, Web : http://www.observatorysciences.co.uk
8 Sussex Innovation Centre Phone : (UK)+(0)1223-655603 (VoIP)
Science Park Square (UK)+(0)1273-704759 (landline)
University of Sussex (UK)+(0)7913-720806 (mobile)
Falmer, BRIGHTON.
BN1 9SB
U.K.
===============================================================================
- Replies:
- RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.
- Navigate by Date:
- Prev:
INP field length Steve Kinder
- Next:
RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
<2010>
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: INP field length Dirk Zimoch
- Next:
RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
<2010>
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024