1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Virtual circuit disconnect - caRepeater bug?
From: "Oleg Makarov" <[email protected]>
To: <[email protected]>, <[email protected]>
Date: Mon, 6 Feb 2012 20:12:44 -0600

Is a caRepeater bug was introduced starting from Epics 3.14.12?

It is intermittent, and may occur when "Related Display" button on an medm screen is pressed.

We were able to reproduce "Virtual circuit disconnect" message (see below) with Epics 3.14.12, Epics 3.14.12.1, and Epics 3.14.12.2 but not with Epics 3.14.11.

Other observations:

1) Workstations with Epics 3.14.11 do not experience such "Virtual circuit disconnect" problem with the same IOC, so this bug is likely on a client side.

2) MEDM build with Epics 3.14.12.2 does not experience such "Virtual circuit disconnect" problem while running on a workstation with Epics 3.14.11 installed.

Is this bug in the caRepeater code?

Any suggestions?

 

Regards,

Oleg Makarov

 

 

 

Mon Feb 06 18:19:30 CST 2012

medmCAExceptionHandlerCb: Channel Access Exception:

Channel Name: Unavailable

Native Type: Unavailable

Native Count: 0

Access: Unavailable

IOC: Unavailable

Message: Virtual circuit disconnect

Context: bl3ioc1.gmca.aps.anl.gov:5064

Requested Type: TYPENOTCONN

Requested Count: 0

Source File: ../cac.cpp

Line number: 1214

Attachment: medm_message.png
Description: PNG image

Attachment: medm_version.png
Description: PNG image


Replies:
RE: Virtual circuit disconnect - caRepeater bug? Hill, Jeffrey O

Navigate by Date:
Prev: RE: EPICS IOC NFS mount and TFTP issue for the mvme3100 board, please help, urgent !!! Zhu, Lixin
Next: RE: errors in vxWorks-6.9/target/h(eader) files when building base 3.14.12.1 Vesna Samardzic-Boban
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: Charged Particle detectors? Mark Rivers
Next: RE: Virtual circuit disconnect - caRepeater bug? Hill, Jeffrey O
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024