Experimental Physics and Industrial Control System
Hi Emma,
I'm not an expert in either the Gateway or sscan & saveData, but:
On 2012-04-01 Emma Shepherd wrote:
> We are using Gateway Version 2.0.3.0 and EPICS base 3.14.9 running on
> CentOS 4.4. Has anybody been looking into this issue yet?
There is a fairly important piece of functionality missing from those versions
of the Gateway and CAS library; to properly pass ca_put_callback() operations
through it you really need to upgrade to Gateway 2.0.4.0 on Base 3.14.11 or
later. Now I can't actually find any calls to ca_put_callback() in a few of
the versions of the sscan and saveData code we have installed here, so I don't
know if an upgrade might fix this or not, but I might be missing something in
how that client works and it might still be trying to use that functionality
somehow.
Are both of the IOCs also built against Base 3.14.9 or are they using a later
version?
- Andrew
--
Never interrupt your enemy when he is making a mistake.
-- Napoleon Bonaparte
- References:
- casStrmClient.cc error: invalid channel identifier Emma Shepherd
- Navigate by Date:
- Prev:
Re: What is void* puser in ca_create_channel Florian Feldbauer
- Next:
Re: casStrmClient.cc error: invalid channel identifier Tim Mooney
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
<2012>
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
RE: casStrmClient.cc error: invalid channel identifier Hill, Jeffrey O
- Next:
asyn w/serial device pushing data Fong, Nia W.
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
<2012>
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024