1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Tektronix 3014 Tracing Problem
From: Eric Norum <[email protected]>
To: Trevor Downer <[email protected]>
Cc: Yujong Kim <[email protected]>, EPICS Tech Talk <[email protected]>
Date: Fri, 7 Dec 2012 20:33:55 -0800
Is the scope triggering?

On Dec 7, 2012, at 5:35 PM, Trevor Downer <[email protected]> wrote:

> Hello again!
> 
> We were able to get the cartesian plot function to work.
> 
> I attached a screenshot of the display after our success.
> 
> Thanks for your help with that!
> 
> The problem was with the MEDM installation, so I re-installed MEDM.
> 
> We were able to make a cartesian plot correctly using another application.
> 
> However, we still are not getting the trace data from the oscilloscope.
> 
> I attached screenshot is of the result that I get when I run the caget
> command on one of the wave form records.
> 
> This is the same result that I get for the other waveform records as well.
> 
> We tried changing the EPICS_CA_MAX_ARRAY_BYTES variable in the
> environment, the envParams, and the st.cmd script from 10000 to
> 100000000, but to no avail as we are still not able to get a trace.
> 
> We also tried changing the NELM field in the waveform records from
> 10000 to 100000 and bigger, and we had the same result.
> 
> Any help that you can give us would be greatly appreciated!
> 
> Thanks
> 
> 
> 
> 
> 
> 
> 
> On Fri, Dec 7, 2012 at 12:10 PM, Hartman, Steven M. <[email protected]> wrote:
>> 
>> On Dec 6, 2012, at 11:51 PM, Yujong Kim wrote:
>>> We can control all main functions of the scope from EPICS MEDM OPI panels without any problem.
>> 
>> Hi Yujong--
>> 
>> To isolate whether this is an medm configuration issue or a CA configuration issue (e.g., EPICS_CA_MAX_ARRAY_BYTES), try to caget the waveform from the computer running medm.
>> 
>> --
>> Steven Hartman
>> [email protected]
>> 
>> 
>> 
> <chan2ScaledWaveWF.png><oscope_with_cartesian.png>

-- 
Eric Norum
[email protected]






Replies:
Re: Tektronix 3014 Tracing Problem Pavel Maslov
References:
Tektronix 3014 Tracing Problem Trevor Downer
Re: Tektronix 3014 Tracing Problem Eric Norum
Re: Tektronix 3014 Tracing Problem Pavel Maslov
Re: Tektronix 3014 Tracing Problem Yujong Kim
Re: Tektronix 3014 Tracing Problem Hartman, Steven M.
Re: Tektronix 3014 Tracing Problem Trevor Downer

Navigate by Date:
Prev: Re: Tektronix 3014 Tracing Problem Trevor Downer
Next: Re: Tektronix 3014 Tracing Problem Pavel Maslov
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Tektronix 3014 Tracing Problem Trevor Downer
Next: Re: Tektronix 3014 Tracing Problem Pavel Maslov
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  <20122013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024