On 2/25/14, 11:20 AM, David Michel wrote:
>> Depending on what platform your IOC is running, you could potentially
>> execute the platform's ping program from your C function. This would
>> allow you to ping without running your IOC as root.
>
> That's exactly what I was doing. On Linux (Ubuntu).
>
>> if you can make a small change to your black box, is to run a simple
>> server on your black box that listens on a TCP or UDP port. You
>> could then use asyn or StreamDevice on your IOC to send a tiny
>> request to that server.
>
> Yes, that could be an option - Similarly, I was thinking I could
> perhaps run an "dummy" IOC with a "dummy" record that is queried from
> the other IOC. This way, I can use the builtin PVExistTest routine
> that will notify the IOC and my OPI rather quickly and without much
> development effort.
>
> What I'm not sure of with this approach is how to turn the
> "disconnected" information into say a bi record with 1 for connected
> and 0 for disconnected ??
Hi, David.
If you're willing to install an IOC on your black box and your existing
IOC can communicate with it, then you could just have a record instance
on your existing IOC with a CA input link (i.e. Channel Access INLINK)
referencing a PV on your black box IOC. For example, if on your
black box IOC you had a longout record instance named "blackBox:id",
you could have a longin record instance on your existing IOC named
"exisiting:idOfBlackBox" with its INP field set to "blackBox:id CP
NMS". Now, if your existing IOC loses communication with the black box
IOC, the longin record instance's STAT and SEVR fields will go to some
value other than NO_ALARM, and you can detect this with another record
instance to make your bi record instance be 1 for connected and 0 for
disconnected. Or you could just make your OPI observe the STAT or SEVR
fields of "existing:idOfBlackBox" and react accordingly.
If you wanted to be fancier, you could make the black box IOC have a
record instance named "blackBox:heartbeat" which cycles periodically
between 0 and 1. Monitor that PV from your existing IOC and add logic
to detect when the black box heartbeat value does not change at the
expected interval.
If you want to stick with your approach of executing the ping program
from a C function, I suspect there's some way for the function to set
a value (e.g. 0 for disconnected and 1 for connected) of one of the
fields of the aSub record instance. I've never used the aSub record,
though, so I couldn't say for sure without looking at the aSub record or
documentation.
Another approach that would work with your C function approach would
be to call your C function from an EPICS SNL program [1]. Based on
the return status of the C function, you could set an EPICS PV in the
SNL program to 0 or 1 using the pvPut function. That would be pretty
straightforward.
Lewis
1. http://www-csr.bessy.de/control/SoftDist/sequencer/index.html
- Replies:
- Re: Monitoring whether an IP device is connected or not David Michel
- References:
- Monitoring whether an IP device is connected or not David Michel
- Re: Monitoring whether an IP device is connected or not J. Lewis Muir
- Re: Monitoring whether an IP device is connected or not David Michel
- Navigate by Date:
- Prev:
Re: Error in building epics base-3.15.0.1 on windows XP (32 bit) using mingw Xiaoqiang Wang
- Next:
Re: Error in building epics base-3.15.0.1 on windows XP (32 bit) using mingw Xiaoqiang Wang
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
<2014>
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: Monitoring whether an IP device is connected or not David Michel
- Next:
Re: Monitoring whether an IP device is connected or not David Michel
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
<2014>
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024