1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 <2015> 2016 2017 2018 2019 2020 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 <2015> 2016 2017 2018 2019 2020 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: Read record field in asynDriver |
From: | Ralph Lange <[email protected]> |
To: | EPICS Tech-Talk <[email protected]> |
Date: | Fri, 20 Feb 2015 15:59:37 +0100 |
Hi Mark, On 20/02/2015 15:24, Mark Rivers wrote:
If we put info items with the by-channel configuration info into the records, we can loop over all records and search for those items when initializing the card, and do the by-channel initialization at that point.I don't think I understand. What code is doing the steps you outline above?
A static routine that the card configuration call (from st.cmd) hooks to initHookAtBeginning. So that the low-level channels are configured after the DB is loaded (and info items are accessible), but before processing starts.
~Ralph