1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 <2018> 2019 2020 2021 2022 2023 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 <2018> 2019 2020 2021 2022 2023 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: Motor Record not moving distances less than .5 |
From: | Kevin Peterson <[email protected]> |
To: | "Sobhani, Bayan" <[email protected]>, "[email protected]" <[email protected]> |
Date: | Thu, 15 Mar 2018 09:49:50 -0500 |
Alex,If UEIP is "No", the smallest move that can be made is determined by the MRES. If UEIP is "Yes", the smallest move that can be made is determined by the ERES.
What is the value of these fields for your motor: UEIP, MRES, ERES? Kevin