1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: driver support for Gamma Vacuum QPC 4
From: "[email protected]" <[email protected]>
To: "'Abdalla Ahmad'" <[email protected]>, "[email protected]" <[email protected]>, "Martin L. Smith" <[email protected]>
Date: Wed, 11 Apr 2018 06:42:13 +0000

Thank you Abdalla – the protocol file will be very useful and maybe help to augment Martin’s work. There’s lots of useful code from both of you and will considerably shorten our development time.

 

 

From: [email protected] <[email protected]> On Behalf Of Abdalla Ahmad
Sent: 11 April 2018 06:33
To: [email protected]; Martin L. Smith <[email protected]>
Subject: RE: driver support for Gamma Vacuum QPC 4

 

Hi

 

We are using the Gamma QPC for the storage ring and the beamlines. The control is simply done using Stream Device. It works fine but you might get a timeout every couple of hours. Seems like there is a problem with the controller itself. We are controlling it through Ethernet so you might want to try the serial port or ModBus.

Attached is the protocol file we are using for voltage and pressure readings and the channel enable/disable functions. Setpoints and relays control was not required, it is done through the Agilent XGS600 gauge controller.

 

Dear Martin,

 

As I mentioned, we are facing a timeout issue with these controllers, are you facing a similar issue with your solution?

 

Best Regards,

Abdalla.

 

From: [email protected] [mailto:[email protected]] On Behalf Of Phillip Sorensen
Sent: Tuesday, April 10, 2018 5:46 PM
To: [email protected]; Chris Whiting <[email protected]>
Subject: Re: driver support for Gamma Vacuum QPC 4

 

One of our staff has been working on QPC support.  I am not sure what functionality he has reached beyond monitoring.  I have included him on this message.

 

Phil Sorensen

On 04/10/2018 06:01 AM, Jack wrote:

Does anyone use Gamma Vacuum QPC 4 vacuum pump controller ?
Thank you
-- 
  Mauro Giacchini

--

https://img.newoldstamp.com/f/000/049/u818.png

Mauro Giacchini

Control System Specialist  ISTITUTO NAZIONALE DI FISICA NUCLEARE

 

p/f: 0039.049.80.68.558 a: Viale universita' 2, 35020 Legnaro, PD -ITALY- 

e: [email protected] s: yakman000 

 

 

 


Avast logo

Questa e-mail è stata controllata per individuare virus con Avast antivirus.
www.avast.com

 

 

Attachment: smime.p7s
Description: S/MIME cryptographic signature


References:
driver support for Gamma Vacuum QPC 4 Jack
Re: driver support for Gamma Vacuum QPC 4 Phillip Sorensen
RE: driver support for Gamma Vacuum QPC 4 Abdalla Ahmad

Navigate by Date:
Prev: RE: driver support for Gamma Vacuum QPC 4 Abdalla Ahmad
Next: Re: driver support for Gamma Vacuum QPC 4 Martin L. Smith
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: driver support for Gamma Vacuum QPC 4 Abdalla Ahmad
Next: Re: driver support for Gamma Vacuum QPC 4 Martin L. Smith
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024