1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 <2020> 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 <2020> 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | areaDetector/ADEiger question |
From: | John Dobbins via Tech-talk <[email protected]> |
To: | "[email protected]" <[email protected]> |
Date: | Thu, 16 Jan 2020 21:44:08 +0000 |
All,
I am trying to understand the data flow options in areaDetector/ADEiger. (EPICS 7.0.3, areaDetector R3-7, ADEiger R3-5, linux-x86_64))
FileWriter is enabled, Data Source = FileWriter and I see HDF5 files are being written.
The user wants TIFF files so I enable the TIFF file plug-in. Now both HDF5 and TIFF files are being written.
I disable FileWriter and Enable Stream, set DataSource = Stream. Now only TIFF files are being written.
Am I doing this correctly?
Thanks,
John Dobbins
Research Support Specialist
Cornell High Energy Synchrotron Source
Cornell University
www.chess.cornell.edu
|