1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Monitoring sscan record fields. [SEC=OFFICIAL] |
From: | "STARRITT, Andrew via Tech-talk" <tech-talk at aps.anl.gov> |
To: | "EPICS Tech Talk (tech-talk at aps.anl.gov)" <tech-talk at aps.anl.gov> |
Date: | Fri, 3 Jun 2022 06:09:19 +0000 |
Hi EPICS community, I have a question regarding the sscan record. BtW I am using sscan R2-11-5 and base 7.0.6.1 running on CentOS 7.9.2009. I am using the scan1 record to drive positioner 1 in LINEAR mode.
I am using a dummy T1PV bo record. I have setup D01PV to monitor a convenient scalar PV. And I have set ATIME to 1.0 As the scan progresses, with camonitor, I can see the expected updates
for scan1.D01CA, however I do not get any updates for scan1.P1CA. Is this expected? Is there some other sscan record field I need to set
in order to get the P1CA updates posted? I do get updates for P1RA for the previous scan. Any help/advice appreciated. Regards Andrew Starritt Australian Synchrotron. |