1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 <2022> 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Phoebus and dynamic macros |
From: | GAGET Alexis via Tech-talk <tech-talk at aps.anl.gov> |
To: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Wed, 2 Nov 2022 14:17:46 +0000 |
Hello, I’m trying to migrate to Phoebus for our new development and I’d like to be able to set Macro dynamically (for my hundreds of acquisition channel for example). I was able to do that with CSS boy using script. According to https://control-system-studio.readthedocs.io/en/latest/app/display/editor/doc/property_type.html?highlight=macros#macros-property it seems possible also.
But when I applied the example to an “Embedded Display”:
importPackage(Packages.org.csstudio.opibuilder.scriptUtil); var macroInput = DataUtil.createMacrosInput(true); macroInput.put("CHANNEL", PVUtil.getString(pvs[0])); widget.setPropertyValue("macros", macroInput);
I got the following exception :
[..] Caused by: java.lang.Exception: Need Macros, got {CHANNEL=2}
[..]
at org.csstudio.display.builder.model.properties.MacrosWidgetProperty.setValueFromObject(MacrosWidgetProperty.java:53)
CHANNEL=2 because my PV loc://macroValue is set to 2.
seems to come from here but it's not really understandable for me
Is the example incorrect, or is it not usable on an "Embedded Display" I've tried on a simple windows, i got the same result
Thanks in advance
CEA Saclay - DRF/Irfu/DIS/LDISC Bâtiment 472 - pièce 105
|