1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Scan rate '.01 second' not achievable |
From: | "Barrett \(US\), Patrick E via Tech-talk" <tech-talk at aps.anl.gov> |
To: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Fri, 6 Jan 2023 14:18:33 +0000 |
Hello, We have added a scan rate of “.01 second” to our scan menu to have records processed at 100 Hz (10 ms), but we are getting the “Scan rate is not achievable” message. Is this due to the clock rate not being able to match 10ms? What does
the system set the scan rate to when it receives a message like this? We are running on Linux Oracle 8 OS. I would think a 10ms rate would be achievable. Thank you, Patrick Barrett Stage Controller Software Engineer The Boeing Company |