1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 <2023> 2024 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | RE: Sequencer interpretation of PV names with {,} characters |
From: | "Ivashkevych, Oksana via Tech-talk" <tech-talk at aps.anl.gov> |
To: | "Kasemir, Kay" <kasemirk at ornl.gov>, "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Fri, 3 Nov 2023 16:10:05 +0000 |
Thank you Kay, Is pvAssign a version 2.2 addition?
I see it in 2.2 manual and do not in 2.1. I could have an older version. From: Kasemir, Kay <kasemirk at ornl.gov>
If there’s no way to escape macros, you might have to connect programmatically, see “pvAssign” in sequencer manual: /* Initially, don’t assign */ double pv; assign pv to “”; /* Then later in some “init” state */ pvAssign(pv,
“XF:BM-ES{Psh_blade1}Pos”); pvMonitor(pv); |