EPICS Home

Experimental Physics and Industrial Control System


 
1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: About pvPut dafault behavior
From: <[email protected]>
To: "Benjamin Franksen" <[email protected]>
Cc: [email protected]
Date: Tue, 01 Mar 2011 09:34:58 +0900
Hello Ben;

> Ok, so your problem was solved by moving from base-3.14.9 to base-3.14.
11.

I guess so.

> Could you also try 3.14.12? Also, could you verify that "caput -c" 
also
> works as expected?
 
I tested the simple .stt program  to pvPut a value with SYNC-option to
a remote IOC with base-3.14.12 and sncseq-2.0.12. It also worked fine.

In addition, I found that "caput -c" also worked fine with both of the
combinations:

base-3-14-11 and sncseq-2.0.12
base-3.14.12 and sncseq-2.0.12.

> If the latest two versions of base work fine, we can probably feel 
safe
> ignoring the problem, else further investigation is in order.

I'm now feeling safe though I have to do further tests with a different
combination of IOC architectures.

Thanks a lot again!

Cheers
Jun-ichi


----- Original Message -----
> Hello Jun-ichi
> 
> On Monday, February 28, 2011, you wrote:
> > Hi Ben and all;
> >
> > I found that pvPut(var, SYNC) works with base-3-14-11 and sncseq-2.0.
12
> > just fine for a combination of IOCs with different types of
> > architectures.
> > I expect pvPut(var, SYNC) works for other combinations of IOCs 
though I
> > have not yet tested it.
> 
> Ok, so your problem was solved by moving from base-3.14.9 to base-3.14.
11.
> Could you also try 3.14.12? Also, could you verify that "caput -c" 
also
> works as expected?
> 
> If the latest two versions of base work fine, we can probably feel 
safe
> ignoring the problem, else further investigation is in order.
> 
> Cheers
> Ben
> 
> ________________________________
> 
> Helmholtz-Zentrum Berlin für Materialien und Energie GmbH
> 
> Mitglied der Hermann von Helmholtz-Gemeinschaft Deutscher 
Forschungszentren e.V
> 
> Aufsichtsrat: Vorsitzender Prof. Dr. Dr. h.c. mult. Joachim Treusch, 
stv. Vorsitzende Dr. Beatrix Vierkorn- Rudolph
> Geschäftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Prof. Dr. Dr. h.
c. Wolfgang Eberhardt, Dr. Ulrich Breuer
> 
> Sitz Berlin, AG Charlottenburg, 89 HRB 5583
> 
> Postadresse:
> Hahn-Meitner-Platz 1
> D-14109 Berlin
> 
> http://www.helmholtz-berlin.de
> 


References:
About pvPut dafault behavior jun-ichi.odagiri
Re: About pvPut dafault behavior benjamin . franksen
Re: About pvPut dafault behavior jun-ichi.odagiri
Re: About pvPut dafault behavior Benjamin Franksen

Navigate by Date:
Prev: edl2boy? james.rowland
Next: Problem with Motor Record on RTEMS on MVME5500 Jim Eastman
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: About pvPut dafault behavior Benjamin Franksen
Next: Does areadetector drvier support Procilica GE1650 CCD? Silver
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024