1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 <2014> 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 <2014> 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | RE: Interface Labview and EPICS |
From: | Mazanec Tomáš <[email protected]> |
To: | "Gao, Yuan" <[email protected]>, "[email protected]" <[email protected]> |
Date: | Fri, 31 Oct 2014 16:31:23 +0000 |
Hello Here is a nice summary: ftp://ftp.ni.com/pub/branches/uk/handson_followup/epics_ral.pdf We have tried EPICS module in LV 2013 and our-own-way: use of LV AMC module and EPICS streamdevice , both with focus on LV Realtime targets ( PC compatible one). - The first was fine for small sets of variables. - The second just sends structured data with UDP and requires little bit of development on both sides. It is promissing, however AMC will include desired TCP support someday soon. As far as I know about the others: - CA lab doesn't work with LV RT targets, - SNS and ObservatorySciences are not publicly available. We haven't found the right one yet, I'm afraid. How frequently you intend to R/W you data to LV ? Cheers, Tomas Od: [email protected] [[email protected]] za uživatele Gao, Yuan [[email protected]]
Odesláno: 22. října 2014 1:20 Komu: [email protected] Předmět: Interface Labview and EPICS Hello,
I am wondering if someone knows how to interface Labview (Windows system) with the EPICS. I am going to use Labview to control a equipment during my beamtime. It would be convenient if EPICS can write and read numbers from
Labview (e.g. scan).
Thanks,
Yuan Gao
|