1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 <2020> 2021 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 <2020> 2021 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | New releases of the measComp module |
From: | Mark Rivers via Tech-talk <tech-talk at aps.anl.gov> |
To: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Fri, 20 Nov 2020 23:41:27 +0000 |
Folks, Releases 2-5 and 2-5-1 of the measComp module are now available. This is from the R2-5-1 release notes: ******************************** -drvMultiFunction.cpp - Fixed bug in waveform digitizer mode, current channel was being calculated incorrrectly. - Improved poller to reduce the number of error messages when the device is not available. - E-1608::AInScanStart_E1608 (Linux) - Added 5 retries to start waveform acquisition. It appears that sometimes the connect() has not actually completed before acquisition is started, and the device returns a "not ready" status. - Improved error messages when acquisition does not start correctly. - Bug fix for 1-byte message not being sent correctly. - mcBoard_E-1608.cpp (Linux) - Bug fix where lock was not taken when it should be. This is from the R2-5 release notes: ******************************** - Improvements to USB-CTR04/08 support - Added support for reading the 8 digital I/O bits in the MCS scan. This allows capturing the status of input and output bits during a scan. There are now 9 MCS spectra: 8 for the counters and 1 for the digital I/O. - Added ability to select counters to use in the MCS on an individual basis, rather than the first and last counter to use. This also applies to the digital I/O word. - Added an AbsTimeWF waveform record containing the absolute time of each point in waveform digitizer and MCS scans. - Added support for cbDaqInScan and cbDaqSetTrigger on Linux. - Added TrigMode record to control the trigger mode of DaqInScan. - Fixed bugs on Linux when the number of counters selected was not a power of 2. The data could be wrong and it would stop before the number of channels to collect was reached. - Added support for E-DIO24 module on Linux and Windows . - Added autoconverted OPI files for edm, caQtDM, CSS-Boy and CSS-Phoebus. - Updated the version of the Measurement Computing Windows UL library from 6.51 to 6.72. The home page for measComp is here: http://cars.uchicago.edu/software/epics/measComp.html
The documentation is here: http://cars.uchicago.edu/software/epics/measCompDoc.html
The release notes are here: http://cars.uchicago.edu/software/epics/measCompReleaseNotes.html
The source repository is on Github: https://github.com/epics-modules/measComp
Cheers, Mark |