1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 <2024> 2025 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 <2024> 2025 |
<== Date ==> | <== Thread ==> |
---|
Subject: | Re: AreaDetectors - ADPylon |
From: | Mark Rivers via Tech-talk <tech-talk at aps.anl.gov> |
To: | Jörn Dreyer <j.dreyer at hzdr.de>, Donny Domagoj Cosic <Donny.Domagoj.Cosic at irb.hr> |
Cc: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Tue, 30 Apr 2024 13:44:29 +0000 |
Hi Donny,
Please send the complete output when the IOC starts up.
Mark
From: Tech-talk <tech-talk-bounces at aps.anl.gov> on behalf of Donny Domagoj Cosic via Tech-talk <tech-talk at aps.anl.gov>
Sent: Tuesday, April 30, 2024 8:29 AM To: Jörn Dreyer <j.dreyer at hzdr.de> Cc: tech-talk at aps.anl.gov <tech-talk at aps.anl.gov> Subject: Re: AreaDetectors - ADPylon Hi Jörn,
Thank you for the suggestion. I am running the IOC in Linux and this is correctly configured. I was able to use Wong suggestion "make envPaths" to generate this file successfully. However I am still not able to run the st.cmd file. I get the error "syntax error near unexpected token errlogInit(20000). It seems like it is not finding EPICS_BASE. Any suggestions? --- Donny Domagoj Cosic Laboratory for Ion Beam Interactions Ruđer Bošković Institute Bijenička cesta 54 | HR-10 000 Zagreb | CROATIA T: +385 1 4561 041 | @: dcosic at irb.hr | https://urldefense.us/v3/__http://www.irb.hr__;!!G_uCfscf7eWS!bPN0Ned2WfQtvKasArKYVt7OYnyHqT7oxl21oKlGVXBqR3BVyooTU0CR2HINIFvtQUtW8QTJ2biLujCV6jv-mPNCR_5Wrhbr$ Dana 2024-04-30 14:31, Jörn Dreyer via Tech-talk je napisao(la): > Hi, > > if you look into the Makefile of the IOC, its configured for > linux-x84_64. > Are you running Linux or windows? If you are using Windows, you have > to modify the Makefile accordingly. > Otherwise the envPath file will not be created. > > Regards, > > Jörn > > Am Dienstag, 30. April 2024, 12:57:28 MESZ schrieb Donny Domagoj Cosic > via Tech-talk: >> Hello, >> >> I successfully compiled AreaDetects R3-13 and added the ADPylon option >> into the config file with the path to the Pylon SDK (v7.4.0). The >> ADPylon module was created and I followed the instructions for reading >> the XML file from a Basler Camera and created the db and adl files >> using >> ADGenICam. >> I modified the st.cmd file in the ADPylon IOC with the address of the >> camera I want to connect to but when I run the st.cmd file I noticed >> that the envPaths file is missing from the folder. >> >> Do I have to separately compile the ADPylon IOC? If I try this, I get >> an >> error that I am missing the Pylon library even though the path is >> defined to "/opt/pylon/". Could this be because I am using a newer >> version of Pylon SDK? Which version has been tested with this IOC? >> >> Additionally, after I start the IOC, how can I display the video from >> the camera in CS-Studio Pheobus? >> >> Thank you in advance, >> |