Hello Bo
Can you give examples for the two different replies? Is there any information in the replies you want to use? Can there be any error-replies (e.g. something like „cannot switch on right now“)?
Dirk
> Am 23.05.2024 um 21:19 schrieb boj via Tech-talk <tech-talk at aps.anl.gov>:
>
> Dear all
>
> I am implementing a StreamDevice based IOC for a "CryoTel GT Cooler", which in general is very easy to communicate with, but has some strange behaviors for
> the startup and shutdown commands.
>
> I need to send one of the following commands:
>
> SET SSTOP=1
>
> or
>
> SET SSTOP=0
>
> However, the response is different in the two cases.
>
> I think a "BO" record, should be used, but is there anyway I can have different protocol definitions for the "1" and "0" state?
>
> Alternatively, is there an easy way to separate this into two records?
>
> Thanks in advance
>
> Bo
- Navigate by Date:
- Prev:
Re: CryoTel GT Cooler: different startup and shutdown StreamDevice protocols Ralph Lange via Tech-talk
- Next:
Re: CryoTel GT Cooler: different startup and shutdown StreamDevice protocols boj via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
<2024>
2025
- Navigate by Thread:
- Prev:
Re: CryoTel GT Cooler: different startup and shutdown StreamDevice protocols boj via Tech-talk
- Next:
PyDevice support VAL field remains 1 Vishnu Patel via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
<2024>
2025