Subject: Re: IOC error message on camonitor disconnect
From: Michael Davidsaver <[email protected]>
To: Andrew Johnson <[email protected]>, [email protected]
Date: Mon, 31 Jul 2017 18:33:33 +0200
On 07/31/2017 06:28 PM, Andrew Johnson wrote:
...
> Question about your change to caserverio.c: Presumably it is possible
> for cas_send_bs_msg() to be called with both lock_needed and
> pclient->disconnect true? Won't this also need
> 
>     if ( lock_needed ) {
>         SEND_UNLOCK(pclient);
>     }
> 
> in the "if ( pclient->disconnect ) {" path before returning?

Yup, my mistake.

References:
Re: IOC error message on camonitor disconnect Michael Davidsaver
Re: IOC error message on camonitor disconnect Michael Davidsaver
Re: IOC error message on camonitor disconnect Andrew Johnson

Navigate by Date:
Prev: Re: IOC error message on camonitor disconnect Andrew Johnson
Next: Re: IOC error message on camonitor disconnect Michael Davidsaver
Index: 2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: IOC error message on camonitor disconnect Andrew Johnson
Next: Re: IOC error message on camonitor disconnect Michael Davidsaver
Index: 2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
ANJ, 21 Dec 2017 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·