Experimental Physics and
| |||||||||||||||
|
I'm using gateway2_0_0_0Beta8 (with R3.14.6) and have some strange problems: 1. The archiver gets a lot more data. Is ADEL ignored through the gateway? Does the gateway make DBE_VALUE monitors from DBE_LOG monitors? I tried '-mask avl' but that didn't help. If the gateway does not preserve the type of monitor (v or l), why not? 2. The alarm handler cannot reset alarms in global mode. The documentation says it can. Do I need some special command line option? 3. When I write to a motor record through the gateway, the complete medm display sometimes hangs until the motor has stopped. Gateway 1.3 did even crash here sometimes. Any idea what's wrong? Dirk
| ||||||||||||||