I am trying to learn how to write a driver module which is based on echoDriver.c written by Marty Kramer, which I renamed to drvMarx.c. I have a soft IOC, which includes the drvMarx.c module and which is intended to communicate with some Ethernet device. The network protocol is UDP. Presently the Ethernet device is simulated with a simple Python script which receives text message, converts the text to all upper case and sends this back. The script is working fine.
In drvMarx.c I am calling asynOctetSyncIO->readRawOnce, which fails with a timeout. Here is the code fragment from the read routine in drvMarx.c:
printf( "\n");
printf( "mxRead:before:readRawOnce: data=%s,nbts=%d,oemReason=0x%x\n",
data,*nbytesTransfered,*eomReason);
printf( "\n");
status=pasynOctetSyncIO->readRawOnce( pmxPvt->udpPort,0,data,maxchars,
5,nbytesTransfered,eomReason,"");
printf( "\n");
printf( "mxRead:after:readRawOnce: data=%s,nbts=%d,oemReason=0x%x\n",
data,*nbytesTransfered,*eomReason);
printf( "\n");
This is what I have in my db file:
record( stringout, "$(P):SO:SEND:IT"){
field( DESC, "Send msg")
field( FLNK, "$(P):SI:READ:IT")
}
record( stringin, "$(P):SI:READ:IT"){
field( DESC, "Read msg")
field( DTYP, "asynOctetWriteRead")
field( INP, "@asyn($(P),0,1) $(P):SO:SEND:IT")
}
When I put the string Hello in the stringout record, this is what gets output:
epics> 2010/04/17 10:02:25.337 HM01 queueRequest synchronous
2010/04/17 10:02:25.337 HM01 mxDriver:write addr 0
2010/04/17 10:02:25.337 HM01 lockPort autoConnectOK 1
2010/04/17 10:02:25.337 HM01 flush
drvMarx:mxFlush
2010/04/17 10:02:25.337 HM01 mxDriver:flush addr 0
2010/04/17 10:02:25.337 HM01 mxFlush
2010/04/17 10:02:25.337 asynOctetSyncIO flush
2010/04/17 10:02:25.337 HM01 unlockPort
2010/04/17 10:02:25.337 HM01 write
Hello
2010/04/17 10:02:25.337 HM01:SI:READ:IT devAsynOctet: writeIt
Hello
2010/04/17 10:02:25.337 HM01 mxDriver:read addr 0
mxRead:before:readRawOnce: data=,nbts=0,oemReason=0x0
2010/04/17 10:02:30.338 asynOctetSyncIO readRaw failed 134.79.64.51:9999 UDP timeout: Resource temporarily unavailable
mxRead:after:readRawOnce: data=HELLO,nbts=5,oemReason=0x0
2010/04/17 10:02:30.338 mxRead nbytesTransfered 5
2010/04/17 10:02:30.338 HM01:SI:READ:IT devAsynOctet: readIt failed
Note that some of the output is generated by printf statements I put in the code.
Also note that readRawOnce returns the correct value, which means that it received the data from the python script and yet it failed.
Here is the st.cmd file:
#!../../bin/linux-x86/marx
< envPaths
cd ${TOP}
dbLoadDatabase("dbd/marx.dbd")
marx_registerRecordDeviceDriver(pdbbase)
drvAsynIPPortConfigure("HMx01","134.79.64.51:9999 UDP",0,0,0)
mxDriverInit("HM01",0,0,0,"HMx01")
dbLoadRecords("db/marx.db","P=HM01")
cd ${TOP}/iocBoot/${IOC}
asynSetTraceMask("HM01",0,0xff)
asynSetTraceIOMask("HM01",0,0x2)
iocInit()
## Start any sequence programs
#seq sncExample,"user=whitegrHost"
The big question is why is readRawOnce timing out?
Is there a document describing how to write a device specific asyn device driver? I see examples in the asyn distribution, like the echoDriver.c, but I find it very difficult to decipher those examples. Therefore I am stumbling around, much of the time not knowing what is the correct approach.
Thanks in advance,
Zen
- Replies:
- RE: asyn Driver questions Mark Rivers
- Navigate by Date:
- Prev:
RE: Labview and EPICS on Linux Zhukov, Alexander P.
- Next:
RE: asyn Driver questions Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
<2010>
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
EPICS Training Course in UK, June 7-11th Philip Taylor
- Next:
RE: asyn Driver questions Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
<2010>
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|