1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: force record processing for same parameter value in asyn port driver
From: "Kim, Kukhee" <[email protected]>
To: Mark Rivers <[email protected]>, EPICS Tech Talk <[email protected]>
Cc: "Kurty, Thomas Charles" <[email protected]>, "Weaver, Matt" <[email protected]>
Date: Fri, 30 Mar 2018 20:11:44 +0000

Hi Mark,

 

I am using asyn port driver for LCLS1 mission readiness project,

and now am trying to integrate it with our Beam Synchronous Acquisition (BSA) system.

 

The BSA assumes, data source PV is processed every time, even the PV has same value with the previous processing,
the PV should be processed and should have new timestamp.  The new timestamp is an index key for the BSA.

 

I am using asyn port driver for the data source PVs.

In asyn port driver, if parameter has same value (no change),  it does not make record processing.

Is there any option to make force record processing even no change on the parameter?

 

 

Thank you for your help.

 

Best regards,

Kukhee

-------------------------------------------

Kukhee Kim

SLAC National Accelerator Laboratory

2575 Sand Hill Rd, MS 64

Menlo Park, CA 94025

Email: [email protected]

Phone: (650)926-4912

Fax:   (650)926-3800

 


Navigate by Date:
Prev: Re: How Pilatus (ADPilatus) IOC process image Mark Rivers
Next: RE: force record processing for same parameter value in asyn port driver Kim, Kukhee
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: How Pilatus (ADPilatus) IOC process image Mark Rivers
Next: RE: force record processing for same parameter value in asyn port driver Kim, Kukhee
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
ANJ, 30 Mar 2018 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·