EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: dxp R5-0 available
From: Mark Rivers <[email protected]>
To: "[email protected]" <[email protected]>
Date: Mon, 2 Jul 2018 21:06:31 +0000
Folks,

dxp R5-0 is available.  This is from the Release Notes:

* Added support for the MicroDXP. This is a board-level product sold to OEMs to embed in their products. It is used in some Ketek SDD detectors and in some Vortex electronics from Hitachi. It is similar to the Saturn, i.e. it is a single-element system that does not support mapping. It does not have a Gate input.

* Upgraded the XIA Handel library from 1.1.11 to 1.2.19. This version is 64-bit compatible, so dxp is no longer limited to being built as a 32-bit application.

* Updated the included Plx library for the xMAP from 6.3.1 to 7.1.1.

* Added edl/autoconvert, opi/autoconvert, and ui/autoconvert directories containing the displays that are automatically converted from medm adl files. Add dxpApp/op/Makefile to automatically do the conversions. 

* Improved the medm files with correct size text widgets and correct text update widget data type to improve the conversions.

* Removed support for the CAMAC DXP4C2X. It is no longer supported by Handel and is probably no longer in use anywhere.

* Some old Vortex blue boxes from Radiant only have the EPP (Enhanced Parallel Port) interface. The third-party Windows software that Handel uses for EPP (DLPORTIO) is no longer supported or available. dxp R5-0 supports the EPP interface on 32-bit and 64-bit Linux only.

* Some old Vortex blue boxes from SII/Radiant have a USB-1.0 interface and not USB-2.0. The third-party Windows software used for USB-1.0 is no longer supported or available. dxp R5-0 supports the USB-1.0 interface on 32-bit and 64-bit Linux only.

The documentation is here:
http://cars.uchicago.edu/software/epics/dxpDoc.html

Release notes are here:
http://cars.uchicago.edu/software/epics/dxpReleaseNotes.html

Source and releases are available on Github here:
https://github.com/epics-modules/dxp

Mark


Navigate by Date:
Prev: New releases of areaDetector drivers: ADDexela, ADLightField, ADPerkinElmer, ADPilatus, ADmarCCD, pvaDriver Mark Rivers
Next: measComp R2-1 released Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: New releases of areaDetector drivers: ADDexela, ADLightField, ADPerkinElmer, ADPilatus, ADmarCCD, pvaDriver Mark Rivers
Next: measComp R2-1 released Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
ANJ, 02 Jul 2018 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·