EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Changing ioc logging. Should I use a modified iocLogServer?
From: Tom Cumming via Tech-talk <tech-talk at aps.anl.gov>
To: tech-talk at aps.anl.gov
Cc: Emma Kurz <ekurz at gemini.edu>, Tiffany Shreves <tshreves at gemini.edu>, Hawi Stecher <hstecher at gemini.edu>
Date: Wed, 22 Jul 2020 11:28:42 -1000
I've been tasked with reviewing how we're currently handling ioc logging. Currently, the console concentrators we're using (Perle, WTI) are handling logging.

iocLogServer immediately comes to mind, but I swear that I saw somewhere that it's no longer going to be included in epics. Is that the case? Will it continue to be supported?

iocLogServer also does not conform to our standard logging practices. That means I'd have to change it but I believe these would be changes the community would enjoy.

1) Log rotation on the date/time instead of file size.
2) Individual log files per-ioc.

I'd like some feedback from folks!!!

Thanks, tom.c


Replies:
Re: Changing ioc logging. Should I use a modified iocLogServer? Johnson, Andrew N. via Tech-talk

Navigate by Date:
Prev: Re: database method to copy string to char waveform Johnson, Andrew N. via Tech-talk
Next: Re: Changing ioc logging. Should I use a modified iocLogServer? Johnson, Andrew N. via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
Navigate by Thread:
Prev: Re: database method to copy string to char waveform Johnson, Andrew N. via Tech-talk
Next: Re: Changing ioc logging. Should I use a modified iocLogServer? Johnson, Andrew N. via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
ANJ, 22 Jul 2020 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·