1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
<== Date ==> <== Thread ==>

Subject: FW: medm question of simDetectorIOC
From: Mark Rivers via Tech-talk <tech-talk at aps.anl.gov>
To: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Wed, 16 Aug 2023 17:43:52 +0000

The problem was just a typo in the prefix.

 

From: timesir <mrlong336 at gmail.com>
Sent: Wednesday, August 16, 2023 12:42 PM
To: Mark Rivers <rivers at cars.uchicago.edu>
Subject: Re: medm question of simDetectorIOC

 

thank you very much. it works. :)

 

Mark Rivers <rivers at cars.uchicago.edu> 2023817日周四 01:05写道:

The example IOC in ADSimDetector uses the prefix 13SIM1:.  You started medm with 13SIM_1:, i.e. with an underscore.  That could be the problem.

 

Mark

 

 

From: timesir <mrlong336 at gmail.com>
Sent: Wednesday, August 16, 2023 11:21 AM
To: Mark Rivers <rivers at cars.uchicago.edu>
Subject: Re: medm question of simDetectorIOC

 

Yes, they are running on the same machine and the firewall is down.

 

Mark Rivers <rivers at cars.uchicago.edu> 2023817日周四 00:00写道:

The problem is almost certainly that EPICS Channel Access is not able to connected from the medm client to the simDetector IOC.

 

  • Are medm and the IOC running on the same machine?
  • Is there a firewall running on that machine?  If yes then it needs to allow ports 5064 and 5065 for UDP and TCP, or be disabled.
  • If they are on different machines have you set any of the EPICS_CA_* environment variables?  Normally you don’t need to.

 

Mark

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of timesir via Tech-talk
Sent: Wednesday, August 16, 2023 10:57 AM
To: tech-talk at aps.anl.gov
Subject: medm question of simDetectorIOC

 

Hi all,

1. start IOC
../../bin/linux-x86_64/simDetectorApp st.cmd
2. start medm
  cd areaDetector/ADSimDetector/simDetectorApp/op/adl
  medm -x -macro "P=13SIM_1:, R=cam1:" simDetector.adl

The following picture shows the effect of medm after startup, why is there nothing in the picture?


References:
medm question of simDetectorIOC timesir via Tech-talk
RE: medm question of simDetectorIOC Mark Rivers via Tech-talk

Navigate by Date:
Prev: RE: medm question of simDetectorIOC Mark Rivers via Tech-talk
Next: Help developing AD plugin Marco A. Barra Montevechi Filho via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
Navigate by Thread:
Prev: RE: medm question of simDetectorIOC Mark Rivers via Tech-talk
Next: Help developing AD plugin Marco A. Barra Montevechi Filho via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
ANJ, 16 Aug 2023 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·