EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: MEDM crash when "Plot Array" of sscan detector with large value
From: "Mark Rivers" <[email protected]>
To: "Tim Mooney" <[email protected]>, "Andrew Johnson" <[email protected]>
Cc: [email protected]
Date: Tue, 20 Jul 2010 09:23:49 -0500
Was Lewis running with an XRT/Graph or SciPlot build?

Mark


-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Tim Mooney
Sent: Tuesday, July 20, 2010 8:23 AM
To: Andrew Johnson
Cc: [email protected]
Subject: Re: MEDM crash when "Plot Array" of sscan detector with large
value



On 7/19/2010 5:30 PM, Andrew Johnson wrote:
> Tim,
>
> On Monday 19 July 2010 16:54:46 Tim Mooney wrote:
>> Lewis,  Just for completeness, I see this on my system as well.
>
> Are you seeing this on a version of MEDM that is build with XTR/Graph,
or with
> SciPlot?  Janet's /usr/local/epics/extensions/bin/<arch>/medm binaries
are
> built with XRT/Graph on Solaris and Linux I believe, and if they show
the
> problem I think it will increase the pressure for Janet to work on a
fix.  We
> need to make sure this gets on her list when she gets back (I think
she's on
> vacation at the moment).

I'm crashing /usr/local/epics/extensions/bin/solaris-sparc/medm, which
I've
verified is built with XRT/Graph.

I also ran MEDM built with SciPlot 
(/APSshare/epics/extensions_2009_07_22/bin/solaris-sparc64-v10-gnu/medm)
, and 
that didn't crash.


>> I could get the sscan record to avoid posting PV's that contain
>> NaN's, but I have a lot of other stuff that also gets plotted,
>> and that also can post NaN's, so my plan is to sit tight until
>> we know whether/when MEDM will be fixed.
>
> It certainly makes sense to fix MEDM rather than try to avoid
generating bad
> data everywhere.
>
> - Andrew

-- 
Tim Mooney ([email protected]) (630)252-5417
Software Services Group, Advanced Photon Source, Argonne National Lab.


Replies:
Re: MEDM crash when "Plot Array" of sscan detector with large value J. Lewis Muir
Re: MEDM crash when "Plot Array" of sscan detector with large value Eric Norum
References:
MEDM crash when "Plot Array" of sscan detector with large value J. Lewis Muir
Re: MEDM crash when "Plot Array" of sscan detector with large value Tim Mooney
Re: MEDM crash when "Plot Array" of sscan detector with large value Andrew Johnson
Re: MEDM crash when "Plot Array" of sscan detector with large value Tim Mooney

Navigate by Date:
Prev: Re: MEDM crash when "Plot Array" of sscan detector with large value Tim Mooney
Next: Re: MEDM crash when "Plot Array" of sscan detector with large value J. Lewis Muir
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: MEDM crash when "Plot Array" of sscan detector with large value Tim Mooney
Next: Re: MEDM crash when "Plot Array" of sscan detector with large value J. Lewis Muir
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 02 Sep 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·