Hi Peter,
On 03/15/2015 10:42 AM, D Peter Siddons wrote:
> I've attached a medm screen. I'm having problems with the Bar Monitor
> widget.
>
> In edit mode:
>
> Setting direction to "up" gives:
> *** stack smashing detected ***: medm terminated
>
> Setting display precision to User Specified gives:
> SIGSEGV
>
> [1]+ Aborted (core dumped) medm scintscal.adl
>
> This is with medm-3.1.9 and epics base-3.14.12.4 on Ubuntu 14.10.
I built medm-3.1.9 on Ubuntu 14.04-LTS and just managed to get a SIGSEGV
from it when playing around with User Specified, but couldn't replicate
it yet when running under gdb.
- Andrew
--
Light thinks it travels faster than anything but it is wrong.
No matter how fast light travels, it finds the darkness has
always got there first, and is waiting for it.
-- Terry Pratchett, Reaper Man
- Replies:
- Re: MEDM issues Jennings, Guy
- References:
- MEDM issues D Peter Siddons
- Navigate by Date:
- Prev:
RE: Asyn record proccessing( read functions) during PINI=YES Mark Rivers
- Next:
Re: SNL: state change statement in entry block Eric Williams
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: MEDM issues Jennings, Guy
- Next:
Re: MEDM issues Jennings, Guy
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
|