That is not true. If you simply comment out the SmartStageName lines in the stages.ini file then the controller works fine with any motor disconnected.
Mark
Sent from my iPhone
> On Jul 10, 2015, at 3:10 PM, Kevin Peterson <[email protected]> wrote:
>
> One disadvantage of the Newport XPS controller is that the controller
> requires its configuration to match the stages that are physically
> connected. If one stage is disconnected from the controller, none of
> the other axes will be usable until the unused axis is reconfigured to
> be a dummy axis. For stable setups this isn't an issue. For
> frequently-changing setups this can be quite annoying.
>
> Kevin
>
>> On 7/10/15 9:58 AM, Mark Rivers wrote:
>> We have 11 Newport XPS controllers on our beam lines. In my
>> experience they are much easier to configure than the Delta Tau
>> units. They have a user-friendly Web interface, all parameters are in
>> engineering units, etc. There is an EPICS interface to complex
>> multi-axis coordinated motion with detector triggering, and lots of
>> other auxiliary I/O.
>>
>> Mark
>>
- Replies:
- RE: Stepper Motor Controllers Mark Rivers
- References:
- Stepper Motor Controllers Mark Davis
- Re: Stepper Motor Controllers Mark Rivers
- Re: Stepper Motor Controllers Kevin Peterson
- Navigate by Date:
- Prev:
Re: Stepper Motor Controllers Kevin Peterson
- Next:
Re: Sequencer on Windows: co-maintainer needed Benjamin Franksen
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
- Navigate by Thread:
- Prev:
Re: Stepper Motor Controllers Kevin Peterson
- Next:
RE: Stepper Motor Controllers Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
<2015>
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025